KIMGUARD ONE-STEP Sterilization Wrap
Kimberly-Clark Health Care
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
KIMGUARD ONE-STEP® Sterilization Wraps are intended to enclose another medical device that is to be sterilized by a healthcare provider using: /g120 V-PRO ® 60 Low Temperature Sterilization System that include: o Lumen Cycle o Non Lumen Cycle o Flexible Cycle KIMGUARD ONE-STEP® Sterilization Wrap (KC100, KC200, KC300, KC400, KC500 and KC600) are intended to allow sterilization of the enclosed medical device(s) and also maintain sterility of the enclosed device(s) until used. Test results validated that KIMGUARD ONE-STEP ® Sterilization Wraps (KC100, KC200, KC300, KC400, KC500, and KC600) allowed sterilization of the enclosed devices by the V-PRO® 60 Low Temperature Sterilization System (i.e., Lumen, Non Lumen, and Flexible Cycles). Additionally, the KIMGUARD ONE-STEP® Sterilization Wrap was validated to allow effective aeration under the pre-programmed sterilization cycles. All models of the KIMGUARD ONE-STEP® Sterilization Wrap (KC100, KC200, KC300, KC400, KC500, and KC600) have been validated for use with the V-PRO® 60 Low Temperature Sterilization System cycles in Table 1. KIMGUARD ONE-STEP® Sterilization Wraps (KC100, KC200, KC300, KC400, KC500, and KC600) Recommendations for Use with the V-PRO® 60 Low Temperature Sterilization System are provided in Table 2. TABLE 1: Validated V-PRO® 60 Low Temperature Sterilizer System Cycles V-PRO® 60 Low Temperature Sterilizer Cycles Intended Load Lumen Cycle Reusable metal and non-metal medical devices including instruments with diffusion-restricted spaces (such as the hinged portion of forceps or scissors) and single, dual or triple channeled rigid/semi-rigid endoscopes, with the following configurations: /g120 Single or dual channeled devices with stainless steel lumens with o An inside diameter of 0.77 mm or larger and a length of 410 mm or shorter /g120 Triple channeled devices with stainless steel lumens with o An inside diameter of 1.2 mm or larger and a length of 257 mm or shorter. o An inside diameter of 1.8 mm or larger and a length of 310 mm or shorter or o An inside diameter of 2.8 mm or larger and a length of 317 mm or shorter Non Lumen Cycle Reusable metal and non-metal non-lumened medical devices including non-lumened rigid, semi-rigid and flexible endoscopes and medical devices with stainless steel or titanium diffusion-restricted spaces such as the hinged portion of forceps or scissors. Flexible Cycle Single or dual channeled Flexible Surgical Endoscopes or Bronchoscopes with lumens that have: /g120 An inside diameter of 1 mm or la rger and a length of 990 mm or shorter. TABLE 2: Recommended Loads for KIMGUARD ONE-STEP® Sterilization Wrap (KC100, KC200, KC300, KC400, KC500, & KC600) for use with V-PRO® 60 Low Temperature Sterilizer System KIMGUARD ONE-STEP® Sterilization Wrap Models Intended Loads1 Maximum Wrapped Package Content Weights Used in Sterility Maintenance Validation Study2 Description of Loads Used in Sterility Maintenance Validation Study2 KC100 Very Light Weight Package (for example batteries) 3 lbs. 3 lb of metal mass 6 surgical forceps 1 self-contained biological indicator (SCBI) (no tray was included) KC200 Light Weight Package (for example telescope with light cord) 6.5 lbs. /g120 2.5 lbs metal mass /g120 6 surgical forceps /g120 1 SCBI /g120 V-PRO tray (17” x 10” x 3½”) at 4 lbs KC300 Light to Moderate Weight Package (for example: general use medical instruments) 9 lbs. /g120 5 lbs metal mass /g120 6 surgical forceps /g120 1 SCBI /g120 V-PRO tray (17” x 10” x 3½”) at 4 lbs KC400 Moderate to Heavy Weight Package (for example: general use medical instruments) 12 lbs. /g120 8 lbs metal mass /g120 6 surgical forceps /g120 1 SCBI /g120 V-PRO tray (17” x 10” x 3½”) at 4 lbs KC500 Heavyweight Package (for example: general use medical instruments) 12 lbs. /g120 8 lbs metal mass /g120 6 surgical forceps /g120 1 SCBI /g120 V-PRO tray (17” x 10” x 3½”) at 4 lbs KC600 Very Heavy Weight Package (for example: general use medical instruments) 12 lbs. /g120 8 lbs metal mass /g120 6 surgical forceps /g120 1 SCBI /g120 V-PRO tray (17” x 10” x 3½”) at 4 lbs 1 Individual results may differ due to factors such as variations in handling practices, wrapping techniques, and folding methods. Results may also differ due to the use of irregularly shaped contents, which may put added stress on the wrap. Each healthcare facility should determine for itself which wrap model is most appropriate for each intended use. 2 It is recommended to not exceed the maximum wrapped package content weights indicated for each wrap model. Furthermore, it is recommended to not exceed the number, weight, and size of individual content types that were validated for KIMGUARD ONE- STEP® Sterilization Wraps.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。