FDA DEVICE FACTS
Pre-vacuum Tabletop Autoclave
Tuttnauer U.S.A Co, Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The ELARA-11 is a table-top autoclave designed for sterilizing medical and surgical goods, including both wrapped and unwrapped, solid, hollow, and porous products and goods defined as hollow A (e.g., dental hand pieces; suction pipes) in ophthalmic, dental, medical clinics; and in first aid rooms. The ELARA-11 is validated for use in sterilizing lumened device of no longer than 230 nun and no smaller than 3.4 mm for sterilization programs 2 and 4. The ELARA-11 is validated for use in sterilizing fabric packs/textiles for sterilization programs 2 and 4. The ELARA-11 is validated for use in sterilizing up to six dental handpieces for sterilization programs 2 and 4. The Model 5075 HSG is a horizontal autoclave designed for the sterilization of wrapped and unwrapped instruments and related items found in dental, medical and veterinary clinics, first aid rooms, and hospitals. The Model 5075 is validated for use in sterilizing lumened device of no longer than 370 mm and no smaller than 3.8 mm for sterilization programs 2 and 3. The Model 5075 is validated for use in fabric packs/textiles for sterilization programs 2 and 4. Programs: Key program features, including cycle times, temperature, dry times, and descriptions of each program for each device are listed in the following charts: ELARA-11 Chamber Diameter 280 mm (11") Chamber Depth 504 mm (19.8") Chamber Volume 28.5 liters (7.5 gal) Maximum load 8.0 kg (17.6 Ibs) Program Description Sterilization Sterilization Dry Time Temperature Time (minutes) (minutes) (CC/°F) 1 Unwrapped instruments | 134/273 4 1 2 Wrapped instruments 134/273 4 20 3 Unwrapped delicate 121/250 20 1 instruments 4 Wrapped delicate 121/250 20 20 instruments Test 1 Bowie & Dick 134/273 3.5 2 Test 2 Vacuum Test N/A Test time 5+10 | N/A Sterilization programs 2 and 4 can be used for sterilizing lumened device of no longer than 230 mm and no smaller than 3.4 mm. Sterilization programs 2 and 4 can be used in sterilizing fabric packs/textiles. Sterilization programs 2 and 4 can be used in sterilizing up to six dental handpieces. All sterilization programs utilize a pre-vacuum step Model 5075 HSG (Chamber Diameter 49.4 cm (26.0") Chamber Depth 75.0 cm (29.5") Chamber Volume 160 liters (42.3 gal) Maximum Load 15 kg (33 Ibs) Program Description Sterilization Sterilization Dry Time | Max Load Temperature Time (minutes) (CC/°F) (minutes) 1 Unwrapped 134/273 4 1 15kg instruments 2 Wrapped 134/273 4 20 15kg instruments 3 Unwrapped 121/250 20 1 15kg delicate instruments 4 Wrapped delicate | 121/250 20 20 15kg instruments Test 1 Bowie & Dick 134/273 3.5 2 ~ Test 2 Vacuum Test N/A Test time 5+10 | N/A = Sterilization programs 2 and 3 can be used in sterilizing lumened device of no longer than 370 mm and no smaller than 3.8 mm. Sterilization programs 2 and 4 can be used in sterilizing fabric packs/textiles. All sterilization programs utilize a pre-vacuum step
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。