EOGas 4 Ethylene Oxide Gas Sterilizer

Andersen Sterilizers, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATENovember 18, 2015PRODUCT CODEFLF

Indications for use

The EOGas 4 Ethylene Oxide Gas Sterilizer is intended for use in hospitals and other human healthcare settings. It is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The 3 hour cycle at 50°C in the EOGas 4 Ethylene Oxide Gas Sterilizer is for surface sterilization of medical devices as well as for the sterilization of single-lumen flexible endoscopes. The critical process parameters for the cycle are summarized in Table 1. Table 1. Critical parameters for the 3 hour cycle in the EOGas 4 Ethylene Oxide Gas Sterilizer EO Amount Temperature Relative Humidity EO Exposure Time Total Cycle Time 17.6¢g+5% 50°C + 3°C 35-70% 3 hours 3.5 hours Maximum loads of specific materials and devices that have been validated are listed in Table 2. All validated maximum loads were processed without additional devices in the sterilizer. Table 2. Load and material types validated in the EOGas 4 Ethylene Oxide Gas Sterilizer Device Type Maximum Load Device Examples Required Aeration Metal 24 Ibs (11 kg) Surgical instruments, Metal instruments do not absorb EO; delicate sharps, including those Follow pouch or wrap manufacturer’s with hinges and mated surfaces instructions (Example: Tyvek® pouches and Sterisheet® wrap require > 6 hours at 50°C). Plastic 7.0 Ibs (3.2 kg) Reusable power cords, trocars 24 hours at 50°C; Fabric 6.1 lbs (2.8 kg) Reusable cloth gowns, towels Follow manufacturer’s instructions Single-lumen One (1) > 2.0mm ID Gastrovideoscopes, gastrointestinal 12 hours at 50°C; Endoscope(s) <1100mm length; videoscopes Follow manufacturer’s instructions No additional devices Four (4) = 1.2 mm ID Bronchoscopes, bronchovideoscopes, < 700 mm length; cystoscopes, ureteroscopes, No additional devices choledocoscopes Reusable medical devices must be aerated following the instructions of the device manufacturer and the packaging material manufacturer, then released for use after sterilization based on successful inactivation of an EZTest®- Gas Biological Indicator in the Andersen EOGas 4 SteriTest process challenge device.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: September 5, 2026