RARA CRAFT DATABASE for FDA Medical Devices
510(k)K151105

FDA DEVICE FACTS

Smith and Nephew Suture Anchors - 5.0mm Absorbable Polymer Anchor, Smith and Nephew Suture Anchors - TAG Bioraptor Suture Anchor 7209317, 7209318, Smith and Nephew Suture Anchors - Bioraptor 2.3 PK Suture Anchor, Smith and Nephew Suture Anchors - Osteoraptor Suture Anchor, Smith and Nephew Suture Anchors - Twinfix Ultra HA Suture Anchor, Smith and Nephew Suture Anchors - OSTEORAPTOR Curved Suture Anchors, Smith and Nephew Suture Anchors - Ultra Fast-Fix Meniscal Repair System, Ultra Fa

Smith & Nephew, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJuly 28, 2015PRODUCT CODEMAI

Indications for use

The Smith & Nephew 5.0 Absorbable Polymer Anchor is intended for use only for the reattachment of soft tissue to bone for the following indications: Shoulder:

1. Bankart lesion repairs

2. SLAP lesion repairs

3. Acromioclavicular separation repairs

4. Rotator cuff tear repairs

5. Capsular shift or capsulolabral reconstructions

6. Biceps tenodesis

7. Deltoid repairs Foot and Ankle:

1. Hallux valgus repairs

2. Medial or lateral instability repairs/reconstructions

3. Achilles tendon repairs/reconstructions

4. Midfoot reconstructions

5. Metatarsal ligament/tendon repairs/reconstructions Elbow, Wrist, and Hand:

1. Scapholunate ligament reconstructions

2. Ulnar or radial collateral ligament reconstructions

3. Lateral epicondylitis repair

4. Biceps tendon reattachment Knee:

1. Extra-capsular repairs:

a. Medial collateral ligament

b. Lateral collateral ligament

c. Posterior oblique ligament

2. Iliotibial band tenodesis

3. Patellar realignment and tendon repairs, including vastus medialis obliquous advancement

1. Bankart Lesion Repair

2. Rotator Cuff Repair

3. Capsular Stabilization

4. Anterior Shoulder Instability Repair

5. Repair of ligaments and tendons of the elbow, foot, and ankle including the treatment of:

- Bunionectomy

- Lateral ankle instability

- Biceps tendon reattachment These suture anchors are intended for the fixation of soft tissue to bone in the Hip, Shoulder, Foot, Ankle, Elbow, Wrist, Hand and Knee as follows: Hip: Hip capsule repair

- Acetabular labrum reattachment Shoulder: Capsular stabilization

- Bankart repair

- Anterior shoulder instability

- SLAP lesion repairs

- Capsular shift or capsulolabral reconstructions Acromioclavicular separation repairs Deltoid repairs Rotator cuff tear repairs Biceps tenodesis Foot and Ankle: Hallux valgus repairs Medial or lateral instability repairs/ reconstructions Achilles tendon repairs/reconstructions Midfoot reconstructions Metatarsal ligament/tendon repairs/reconstructions Bunionectomy Elbow, Wrist, and Hand: Biceps tendon reattachment Ulnar or radial collateral ligament reconstructions Lateral epicondylitis repair Knee: Extra-capsular repairs:

- Medial collateral ligament

- Lateral collateral ligament

- Posterior oblique ligament Patellar realignment and tendon repairs

- Vastus medialis obliquous advancement Iliotibial band tenodesis The Smith & Nephew OSTEORAPTOR Suture Anchor is intended for the reattachment of soft tissue to bone for the following indications: Elbow, Wrist, and Hand Biceps tendon reattachment Ulnar or radial collateral ligament reconstructions Lateral epicondylitis repair Foot and Ankle Hallux valgus repairs Medial or lateral instability repairs/ reconstructions Midfoot reconstructions Metatarsal ligament/tendon repairs/reconstructions Bunionectomy Hip Hip capsule repair

- Acetabular labrum reattachment Knee Extra-capsular repairs:

- Medial collateral ligament

- Lateral collateral ligament

- Posterior oblique ligament Patellar realignment and tendon repairs

- Vastus medialis obliquous advancement Iliotibial band tenodesis Shoulder Capsular stabilization

- Bankart repair

- Anterior shoulder instability

- SLAP lesion repairs

- Capsular shift or capsulolabral reconstructions Acromioclavicular separation repairs Deltoid repairs Rotator cuff tear repairs Biceps tenodesis The Smith & Nephew TWINFIX Ultra HA Suture Anchor is intended for use for the reattachment of soft tissue to bone for the following indications: Shoulder: Bankart repairs SLAP lesion repairs Capsular shift or capsulolabral reconstructions Acromioclavicular separation repairs Deltoid repairs Rotator cuff tear repairs Biceps tenodesis Foot and Ankle: Hallux valgus repairs Medial or lateral instability repairs/reconstructions Achilles tendon repairs/reconstructions Midfoot reconstructions Metatarsal ligament/tendon repairs/reconstructions Knee: Extra-capsular repairs:

- Medial collateral ligament

- Lateral collateral ligament

- Posterior oblique ligament Patellar realignment and tendon repairs:

- Vastus medialis obliquous advancement Iliotibial band tenodesis Elbow: Ulnar or radial collateral ligament reconstructions Lateral epicondylitis repair Biceps tendon reattachment The Smith & Nephew OSTEORAPTOR Curved Suture Anchor is intended for the reattachment of soft tissue to bone for the following indications: Shoulder: Capsular stabilization

- Bankart repair

- Anterior shoulder instability

- SLAP lesion repairs

- Capsular shift or capsulolabral reconstructions Acromioclavicular separation repairs Deltoid repairs Rotator cuff tear repairs Biceps tenodesis The ULTRA FAST-FIX Meniscal Repair System is intended for use as suture retention devices to facilitate percutaneous or endoscopic soft tissue procedures. The ULTRA FAST-FIX System is indicated for use in meniscal repairs and allograft transplant procedures. The ULTRA FAST-FIX System is intended to be used for anchoring the allograft to the meniscal rim during allograft transplant procedures. The ULTRA FAST-FIX AB Meniscal Repair System is intended for use as a suture retention device to facilitate percutaneous or endoscopic soft tissue procedures. The ULTRA FAST-FIX AB System is indicated for use in meniscal repairs and allograft transplant procedures. The ULTRA FAST-FIX AB System is intended to be used for anchoring the allograft to the meniscal rim during allograft transplant procedures. The FAST-FIX 360 Meniscal Repair System is intended for use as a suture retention device to facilitate percutaneous or endoscopic soft tissue procedures. The FAST-FIX 360 System is intended to be used for anchoring the allograft to the meniscal rim during allograft transplant procedures. The Smith & Nephew HEALICOIL Absorbable Suture Anchor is intended for the reattachment of soft tissue to bone for the following indications: Shoulder: Bankart lesion repairs Slap lesion repairs Capsular shift or capsulolabral reconstructions Acromioclavicular separation repairs Deltoid repairs Rotator cuff tear repairs Biceps tenodesis Foot and Ankle: Hallux valgus repairs Medial or lateral instability repairs/reconstructions Achilles tendon repairs/reconstruction Midfoot reconstructions Metatarsal ligament/tendon repairs/reconstructions Knee: Extra-capsular repairs:

- Medial collateral ligament

- Lateral collateral ligament

- Posterior oblique ligament Patellar realignment and tendon repairs:

- Vastus medialis obliquous advancement Iliotibial band tenodesis Elbow: Ulnar or radial collateral ligament reconstructions Lateral epicondylitis repair Biceps tendon reattachment

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: September 5, 2026