RARA CRAFT DATABASE for FDA Medical Devices
510(k)K152951

FDA DEVICE FACTS

Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, Camera Sterilization Tray

Paragon Medical, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 28, 2015PRODUCT CODEKCT

Indications for use

The Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are intended to enclose and organize Stryker Endoscopy reusable medical instruments during sterilization at a healthcare facility. The trays are optional accessories to the Stryker Endoscopy instruments for which they are designed. The trays are not intended to m aintain sterility; they are intended to be used in conjunction with legally marketed, FDA-cleared sterilization wrap in order to maintain sterility of the enclosed devices. The Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are intended for use in any of the following standard sterilization machines / cycles: No Method Cycle 1 Ethylene Oxide (EtO) Preconditioning Parameters Temperature (°C) 55°C (131°F) Chamber Humidity 70% RH Vacuum Set Points 1.3 psia Time 30 minutes Exposure Concentration 725 mg/L, 100% EO Temperature (°C) 55°C +2°C (131°F +5°F) Time 1 hour Chamber Humidity (%) 70% RH (50-80%) +5% Aeration Aeration Time 12 hours Temperature 35°C - 54°C (95°F – 129°F) 2 Prevacuum Steam Cycle 1 Cycle 2 Wrapping Double Double Temperature 132°C (270°F) 134°C (273°F) Sterilization Time 4 minutes 3 minutes Dry Time 30 minutes 30 minutes 3G r a v i t y S t e a m Cycle 1 Cycle 2 Wrapping Double Double Temperature 132°C (270°F) 134°C (273°F) Sterilization Time 15 minutes 10 minutes Dry Time 30 minutes 30 minutes 4 STERIS® V-PRO® 1 Standard 5 STERIS® V-PRO® 1 Plus Non-Lumen or Lumen 6 STERIS® V-PRO® maX Non-Lumen or Lumen 7 STERRAD® 100S Standard 8 STERRAD® NX® Standard 9 STERRAD® 100NX® Standard In addition, the Advanced Imaging Modality (AIM) Sterilization Tray, Endoscope and Camera Sterilization Tray, and Camera Sterilization Tray are validated for the following Immediate Use Steam Sterilization cycles for emergency situations ONLY. Method Cycle Immediate Use Steam Sterilization (“Flash”) Prevacuum Steam Cycle 1 Cycle 2 Wrapping None None Temperature 132°C (270°F) 134°C (273°F) Sterilization Time 4 minutes 3 minutes Dry Time None None The maximum product loads for the trays are as follows: Tray Description Catalog Number Maximum Tray Product Load Total Loaded Tray Weight Advanced Imaging Modality (AIM) Sterilization Tray 0233-032-301 Camera (Qty. 1) Light Cable (Qty. 1) Coupler (Qty. 1) Scope (Qty. 2) Adapter (Qty. 2) 10.58 lbs Endoscope and Camera Sterilization Tray 233-032-302 Camera (Qty. 1) Light Cable (Qty. 1) Coupler (Qty. 1) Scope (Qty. 2) Adapter (Qty. 2) 10.58 lbs Camera Sterilization Tray 0233-410-002 Camera (Qty. 1) Light Cable (Qty. 1) Coupler (Qty. 1) 8.83 lbs * Validated worst case loading configuration included the Advanced Imaging Modality (AIM) Sterilization Tray containing a camera (Qty. 1), light cable (Qty. 1), coupler (Qty. 2), scope (Qty. 3) and adapter (Qty. 3).

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン