RARA CRAFT DATABASE for FDA Medical Devices
510(k)K161476

FDA DEVICE FACTS

SMR Shoulder System

Lima Corporate S.P.A.

Verified FDA Record identity for medical-device development research. This overview uses only fields stated in the FDA Record and is not a Device Description.医療機器開発の調査用に、確認済みの FDA Record の識別情報を示しています。この概要は FDA Record に記載された項目だけによるもので、機器説明ではありません。

DECISION DATEJune 24, 2016PRODUCT CODEKWT

Indications for use

The SMR Shoulder System is intended for partial or total, primary or revision shoulder joint replacement.

The SMR Anatomic Shoulder System is indicated for partial or total, primary or revision shoulder joint replacement in patients suffering from disability due to:

¢ Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis;

e Inflammatory degenerative joint disease such as rheumatoid arthritis;

e Treatment of acute fractures of the humeral head that cannot be treated with other fracture fixation methods;

e Revision of a failed primary implant;

e¢ §©Cuff tear arthropathy (CTA Heads only).

The SMR Reverse Shoulder System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff deficient joint with severe arthropathy (disabled shoulder). The patient's joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to use the device.

The Modular SMR Shoulder System allows the assembly of components in various humeral and glenoid constructs. The constructs are intended for cemented and uncemented use as specified in the following table.

In the Anatomic shoulder the humeral construct consists of the humeral stem, the humeral body, the adaptor taper and the humeral head. In the Reverse shoulder the humeral construct consists of the humeral stem, the reverse humeral body and the reverse liner. On the humeral side the fixation of the humeral stem determines if the construct is cemented or uncemented.

The Anatomic glenoid construct consists of an all polyethylene glenoid or a metal back assembled with a liner while the Reverse glenoid construct consists of the metal back, the connector and the glenosphere. On the glenoid side, the fixation of the all polyethylene glenoid or the metal back determines if the construct is cemented or uncemented.

seen Components Material Cem Use Not Cem e ° SMR Stems (Cemented, Cemented Revision) Ti6AI4V x e ° SMR Stems (Cementless Finned, Cementless Revision) Ti6AI4V x e SMR Humeral Bodies (Trauma, Finned) Ti6AI4V x x e SMR Reverse Humeral Body Ti6AI4V x x e e Humeral Extension Ti6AI4V x x e SMR Humeral Heads (Standard, CTA) CoCrMo x x ° SMR Adaptor Tapers (Neutral, Eccentric) Ti6AI4V x x

SMR CTA Head Adaptor for Reverse Humeral Body Ti6AI4V xX xX e | SMR Glenospheres CoCrMo x e | SMR Connectors Ti6AI4V xX e | Reverse Liners UHMWPE x x

° SMR Cemented Glenoids UHMWPE x

° SMR 3 Pegs Cemented Glenoids UHMWPE x

° e | SMR Metal Back Glenoids Ti6AI4V+PoroTi x* x*

e e SMR TT Metal Back Baseplate TiGAI4V x* x*

° e | SMRTT Metal Back Peg TiGAI4V x x

° SMR Metal Back Liner UHMWPE x* x*

e* | e | SMR Bone screws Ti6AI4V x

Material Standards Ti6AI4V (ISO 5832-3 - ASTM F1472) - CoCrMo (ISO 5832-12 - ASTM F1537) - UHMWPE (ISO 5834-2 - ASTM F648) - PoroTi Titanium Coating (ASTM F1580)

*NOTE:

e In the US, the SMR Metal Backed Glenoid/Liner construct, used as part of the SMR Anatomic Shoulder Replacement, is intended for use with bone cement and should be used without bone screws.

e The SMR Metal Backed Glenoid/Connector/Glenosphere construct, used as part of the SMR Reverse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.

e The SMR TT Metal Back is indicated for primary implant in anatomic or reverse total shoulder arthroplasty with poor glenoid bone quality or in revision case with consistent bone loss on the glenoid side. The implant is suitable for implantation with or without bone graft. These indications are not yet approved in the US.

e In the US the SMR TT Metal Back Baseplate used as part of the SMR Anatomic Shoulder Replacement, is intended for use with bone cement and should be used without bone screws; while when used as part of the SMR Reverse Shoulder replacement, is intended for uncemented use with the addition of screws for fixation.

e The Dia. 50, 52 and 54 mm Humeral Heads with +3mm increased height cannot be coupled to the Long Adaptor Tapers (both concentric and eccentric)

e The Dia. 52 and 54 mm Humeral Heads with +2mm increased height cannot be coupled to the Long Adaptor Tapers (both concentric and eccentric)

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: September 2, 2026