FDA DEVICE FACTS
Cardinal Health Sterilization Wrap
Cardinal Health200, LLC
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Cardinal Health™ Sterilization Wrap is intended to be used to enclose another medical device that is to be sterilized by a health care provider by using: « Advanced Sterilization Products (ASP) STERRAD® 200 System The wrap is intended to allow sterilization of the enclosed medical device(s) and to maintain sterility of the enclosed devices until it is used. All models of the Cardinal Health™ Sterilization Wrap have been validated for use with the Advanced Sterilization Products (ASP) STERRAD® 200 in Table 1. Table 1 — Validated Advanced Sterilization Products STERRAD® 200 Sterilization Cycle and Intended Load Advanced Sterilization Maximum Products (ASP) | Recommended Intended Load STERRAD® | Chamber Load J System ASP 36.48 Ibs Reusable metal and non-metal medical devices, including up to 12 STERRAD® 200 lumens of the following lumen dimensions per chamber load: e An inside diameter of 1 mm or larger and a length of 125 mm or shorter of single-channel stainless steel lumens e An inside diameter of 2 mm or larger and a length of 250 mm or shorter of single-channel stainless steel lumens « An inside diameter of 3 mm or larger and a length of 400 mm or shorter of single-channel stainless steel lumens ¢ An inside diameter of 6 mm or larger and a length of 310 mm or shorter of a single-channel Teflon®/Polyethyiene lumen Table 2: Wrap Model Recommendations! Maximum Recommended Wrapped Package Content Weights” Sterilization Wrap Model Intended Load Advanced Sterilization Products (ASP) STERRAD® 200 CH100 Very light weight package (for example: towel packs or batteries). 9.12 Ibs Light weight package Ce (for example: telescope with light cord). a2 PS Light to moderate weight package oa (for example: general use medical instruments). a2 Moderate to heavy weight package cs (for example: general use medical instruments). 12 be Heavy weight package CH500 (for example: general use medical instruments). 9.12 bs CH600 Very heavy weight package (for example: general use medical instruments). 9.12 Ibs Individual results may differ due to factors such as variations in handling practices, wrapping techniques, and folding methods. Results may also differ due to the use of irregularly shaped contents, which may put added stress on the wrap. Each healthcare facility should determine for itself which wrap model is most appropriate for each intended use. ? It is recommended to not exceed the maximum wrapped package content weights indicated for each wrap model. Furthermore, it is recommended to not exceed the number, weight and size of individual content types that were validated for the Cardinal Health™ Sterilization Wraps. The following loads were used in the Advanced Sterilization Products (ASP) STERRAD® 200 Sterility Validation Studies: * CH100 - CH600: 23 in. x 11 in. x 4 in. tray containing metal instruments. Note: The loads used in each Sterility Validation Study corresponded to the maximum wrapped package content weights in Table 2.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。