Kent Camera

Kent Imaging, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEMay 5, 2017PRODUCT CODEMUD

Indications for use

Same The Kent Camera is intended for use by healthcare professionals as a non-invasive tissue oxygenation measurement system that reports an approximate value of oxygen saturation (StO2), relative oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) level in superficial tissue. The Kent Camera displays two-dimensional color-coded images of tissue oxygenation of the scanned surface and reports multispectral tissue oxygenation measurements for selected tissue regions. The Kent Camera is indicated for use to determine oxygenation levels in superficial tissues. none Measurements Same  oxygen saturation  relative oxyhemoglobin level  relative deoxyhemoglobin level none Method of Measurement Same Non-invasive, non-patient contacting imaging head illuminates the surface and receives returned light none Minor center wavelength change and increased bandwidth Four wavelengths between 600nm and 1000nm Different. Both use specific weighted coefficients. The change had no effect on performance and does not present any additional safety or effectiveness concerns. A CMOS image sensor with global shutter is used as the detector A wavelength-filtered CMOS image sensor with rolling shutter is used as the detector Similar. Both are CMOS sensors. The change in shutter type had no effect on performance and does not present any additional safety 1440, 720 – 13th Avenue SW, Calgary, Alberta Canada, T2R 1M5 Tel: 403-455-7610 or effectiveness concerns. Same Spectral analysis at specific wavelengths of light returned from the target tissue none Light Source Higher intensity, shorter duration Lower intensity, longer duration Similar. Both use LEDs. The change in LEDs had no effect on performance and does not present any additional safety or effectiveness concerns. Ambient Light Insignificant contribution to image (relative to NIR LEDs) due to short exposure time Blocked by optical filters Different. Both compensate for ambient light. The change in filtering of light had no effect on performance and does not present any additional safety or effectiveness concerns. Excessively Bright Ambient Light Same Checked for in software none Working Distance Approximately 12” Approximately 16” Similar. Both have the same approximate working distance. The change in working distance had no effect on performance and does not present any additional safety or effectiveness concerns. Output Display Same  Two-dimensional color-coded map of estimated oxygen saturation  Numeric data none Power Source DC (battery-powered) AC Different. The device power source was changed from AC to DC (battery-powered). The change from AC to DC (battery-powered) does not affect the oxygenation data provided, had no effect on performance and does not present any additional safety or effectiveness concerns. Patient Contact Same None none 1440, 720 – 13th Avenue SW, Calgary, Alberta Canada, T2R 1M5 Tel: 403-455-7610 Patient Population and Environment Same Healthcare environment for patient population with potential circulatory compromise none Location of Measurement Same Two-dimensional area of superficial tissue none Control Method Same Computer controlled none Calibration Same Preformed at start-up by operator. Performed periodically during extended picture capturing sessions none Sterility Same Camera and components are not supplied sterile, nor are they considered sterile or are to be sterilized none User Interface Same  DC-powered touchscreen PC  DC-powered camera (imaging head) none Computer and a battery incorporated into camera enclosure Stand based design supporting computer, power supply and camera head Different. The update of the camera from the stand-based device to a handheld device involved changes to the power source, overall dimensions and packaging. The change from stand-based to handheld had no effect on performance and does not present any additional safety or effectiveness concerns as the fundamental scientific, multispectral imaging, technology is the same.

Nonclinical Tests To support the substantial equivalence , the modified Kent Camera, like the predicate device before, went through and passed both internal testing for user and design requirements as wel l as international standards. The Kent camera passed testing for the following standards:  Electrical safety and essential performance: ANSI/AAMI ES60601-1  Electromagnetic compatibility: IEC 60601-1-2 1440, 720 – 13th Avenue SW, Calgary, Alberta Canada, T2R 1M5 Tel: 403-455-7610 As mentioned previously, the modified Kent c amera is battery (DC) powered. A medic al grade battery was purchased for this purpose and it is compliant with the following standards:  Battery safety testing: IEC 62133:2012  Transportation safety testing of lithium batteries: UN38.3:2009 The predicate device uses LED s in combination with bandpass filters in front of the detector to illuminate the target within narrow passband s. The subject device uses LEDs with minor changes in center wavelength and no bandpass filters which increase s the bandwidth of each wavelength. Appropriate matching extinction coefficients are employed and weighted in the subject device to reflect the minor wavelength changes and increased bandwidth of each LED emission profile. This results in both cameras having effectively the same performa nce in obtaining StO2 values even in the presence of noise.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 29, 2026