Indications for use
This device is indicated for the orthodontic movement of teeth. It is used temporarily and is removed after This device is indicated for the orthodontic movement of teeth. It is used temporarily and is removed after orthodontic treatment has been completed. The devices are intended to be single use only. orthodontic treatment has been completed. The devices are intended to be single use only. Material Aluminum Oxide Aluminum Oxide
Biocompatibility Meets the applicable requirement of ISO 10993 Meets the applicable requirement of ISO 10993 Maxillary Torque (mm) -21 to +17 -22 to +17 Maxillary Angulation 0 – 9 0 - 11 Slot 0.018″, 0.022″ 0.018″, 0.022″ Transparency Half-transparency Half-transparency Color White, same as tooth color White, same as tooth color Indication system Colored-dot Colored-dot
Design Tie wings for ligature, Hook, Archwire Slot, Round home, base and identification marks for placement Tie wings for ligature, Hook, Archwire Slot, Round home, base and identification marks for placement Hooks for ligation, for additional tooth movement, Molded ceramic body with rounded corners and edges, Slot to hold orthodontic wires Hooks for ligation, for additional tooth movement, Molded ceramic body with rounded corners and edges, Slot to hold orthodontic wires Single Use Yes Yes Non-Sterile Packaging Yes Yes
Non-Clinical Study performance The subject device was found to be in compliance with biocompatibility. The standards which have been applied to the biocompatibility study were ISO 10993 Biological evaluation of medical devices Part 1 – Evaluation and testing in the risk management process, Part 4 - Selection of tests of interactions with blood, Part 5 – Tests for in vitro cytotoxicity and Part 10 – Tests for irritation and delayed-type hypersensitivity.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。