Indications for use
The Multi-Link X2 ECG Adapter and Direct Connect Lead Wire System are used in telemetry to transmit ECG signals from the electrodes to the transmitters on ambulatory patients within a defined coverage area for monitoring purposes. The Multi-Link Direct-Connect Leadwires are single-patient-use, nonsterile and cannot be reprocessed. The Multi-Link Adapters are reusable, nonsterile and can be reprocessed. The Multi-Link X2 ECG Adapter and Direct Connect Lead Wire System are used with any patient population requiring ambulatory ECG, and are compatible with Philips, Mindray and Nihon Kohden electrocardiograph Multi-Link Cable and Lead Wire Systems are reusable electrode cable system used to transmit signals from patient electrodes to various electrocardiograph recorders/monitors from both diagnostic and monitoring purposes. Multi- Link Cable and Lead Wire Systems are limited to indications for use of the connected monitoring or diagnostic equipment. Such equipment is commonly located in hospitals, doctor's offices, and emergency vehicles, as well as in home use The Single Patient Use ECG Lead Wire is an electrode cable systems used to transmit signals from patient electrodes to various electrocardiograph recorders I monitors for both diagnostic and monitoring purposes. Use is limited by the indications for use of the connected monitoring or diagnostic equipment. The Single Patient Use ECG Lead Wire set is intended to be used by trained operators in a medical professional's environment Element of comparison Proposed Device Primary Predicate Device Multi-Link Cable and Lead Wire Systems K980582 Secondary Predicate Device ECG Single Patient Use Lead Wire Set K101660 monitors.
Principle of Operation Adapters and lead wires are cable conductors to conduct ECG signal from patient ECG electrodes to monitoring equipment. Signal is conducted from ECG electrode through insulated signal wires made of conductive material. Signal wires are protected from environmental noise factors with metal shielding around it, acting as Faraday´s cage. The adapters and lead wires have an insulating jacket made of thermoplastics providing electrical insulation. Trunk cables and lead wires are cable conductors to conduct ECG signal from patient ECG electrodes to monitoring equipment. Signal is conducted from ECG electrode through insulated signal wires made of conductive material. Signal wires are protected from environmental noise factors with metal shielding around it, acting as Faraday´s cage. The trunk cables and lead wires have an insulating jacket made of thermoplastics providing electrical insulation. Trunk cables and lead wires are cable conductors to conduct ECG signal from patient ECG electrodes to monitoring equipment. Signal is conducted from ECG electrode through insulated signal wires made of conductive material. Signal wires are protected from environmental noise factors with metal shielding around it, acting as Faraday´s cage. The trunk cables and lead wires have an insulating jacket made of thermoplastics providing electrical insulation. Patient Population Any patient population requiring ECG monitoring Any patient population requiring ECG monitoring Any patient population requiring ECG monitoring Anatomical Sites Chest Chest Chest Environment of Use Hospital Environment Hospitals, doctor's offices, and emergency vehicles, as well as in home use Medical professional's environment Compatibility with environment and other devices Philips, Mindray and Nihon Kohden electrocardiograph monitors GE Healthcare electrocardiograph monitors GE Healthcare electrocardiograph monitors Characteristics Number of lead wires 3, 5 or 6 lead version 3,5 or 12 le ad version 3,5 or 12 lead version Sterility Multi-Link adapters are reusable, nonsterile
Multi-Link direct connect lead wire is single-patient-use, nonsterile Multi-Link trunk cables are reusable, nonsterile
Multi-Link lead wire is reusable, nonsterile Trunk cables are reusable, nonsterile
Lead wire is single-patient-use, nonsterile Element of comparison Proposed Device Primary Predicate Device Multi-Link Cable and Lead Wire Systems K980582 Secondary Predicate Device ECG Single Patient Use Lead Wire Set K101660 Lead wire colors According 60601-2-27 According 60601-2-27 According 60601-2-27 Cable coating materials: Adapters TPU C78A Grey (Munsell N7) Polyurethane, Elastolia N1185A10 Durometer 85A Color-Munsell N7 (GREY) Colorant: TSE RV73442435 Load at 3% TPU 1185A10 Polyurethane: Resin PUR Natural 75D Durometer Color Munsell N7 Grey
N/A
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。