RARA CRAFT DATABASE for FDA Medical Devices
510(k)K170100

FDA DEVICE FACTS

CreoDent Solidex Customized Abutment and Screw

Creodent Prosthetics, Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJuly 18, 2017PRODUCT CODENHA

Indications for use

The CreoDent Solidex® Customized Abutment and Screw is intended for use with an endosseous implant to support a prosthetic device in patients who are partially or completely endentulous. The device can be used for single or multiple-unit restorations. The prosthesis can be cemented or screw retained to the abutment. An abutment screw is used to secure the abutment to the endosseous implant.

The CreoDent Solidex® Customized Abutment and Screw are compatible with the following:

• Sweden & Martina Premium Implant System 3.3mm and 3.8mm

The CreoDent Solidex® Customized Abutment is intended for use with an endosseous implant to support a prosthetic device in patients who are partially or completely edentulous. The device can be used for single or multiple-unit restorations. The prosthesis can be cemented or screw retained to the abutment. An abutment screw is used to secure the abutment to the endosseous implant.

The CreoDent Solidex® Customized Abutment is compatible with the following:

• Biomet 3i Osseotite Certain Dental Implants 3.25mm, 4mm, 5mm, 6mm

• Straumann Bone Level implants 3.3mm, 4.1mm, 4.8mm

Dimensions and Angulations Creodent Solidex Customized Abutment and Screw sizes for

• Sweden & Martina Premium Implant System 3.3mm and 3.8mm

Angles not to exceed up to 20 degrees from the implant axis. Creodent Solidex Customized Abutment sizes for Biomet 3i Osseotite Certain 3.25mm, 4.0mm, 5.0mm and 6.0mm diameter implants. Straumann Bone Level implants 3.3mm, 4.1mm, 4.8mm

Angles not to exceed up to 20 degrees from the implant axis. Non-clinical Testing Data: Static/Fatigue testing was conducted in accordance with ISO 14801:2007E Dentistry- Implants-Dynamic fatigue test for endosseous dental implants with the worst case scenario for the Solidex® Customized Abutment and Screw connection platform. Reverse engineering dimensional analysis was conducted using OEM implant bodies, OEM abutments and OEM abutment screws. Sterilization validation was conducted according to ISO 17665-1 was performed. These results demonstrated that the Solidex® Customized Abutment and Screw have sufficient mechanical strength for their intended clinical application and are compatible with the Sweden & Martina Premium Implant for which they are intended. Biocompatibility information is leveraged from our previous 510k (K150012).

Substantial Equivalence discussion difference: The differences between the subject device and the Primary predicate is the compatible implant bodies. This comparison is for similarity of device not for implant compatibility.

Table #2 Legally marketed predicate device (Abutment) to which equivalence is claimed:

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 29, 2026