Anprolene AN75 Ethylene Oxide Gas Sterilizer

Andersen Sterilizers, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEOctober 31, 2017PRODUCT CODEFLF

Indications for use

The Anprolene AN75 Ethylene Oxide Gas Sterilizer is intended for use in hospitals and other human healthcare settings. It is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The 12 hour cycle at 20-29°C in the Anprolene AN75 Ethylene Oxide Gas Sterilizer is for surface sterilization of medical devices, including mated surfaces. The critical process parameters for the cycle are summarized in Table 1. Table 1. Critical sterilization cycle parameters in the Anprolene AN75 Ethylene Oxide Gas Sterilizer EO Amount Temperature Relative Humidity EO Exposure Time Total Cycle Time 17.6 ¢g+5% 20-29°C (68-84°F) 35-70% 12 hours 14 hours Maximum loads of specific materials and devices that have been validated are listed in Table 2. All validated maximum loads were processed without additional devices in the sterilizer. Table 2. Load and material types validated in the Anprolene AN75 Ethylene Oxide Gas Sterilizer Device Type Maximum Load Device Examples Required Aeration Metal 24 Ibs (11 kg) Delicate sharps and surgical Metal instruments do not absorb EO; instruments, including those Follow pouch or wrap manufacturer’s with hinges and mated surfaces instructions (Example: Sterisheet® wraps require > 6 hours at 20-29°C). Plastic 3.5 Ibs (1.6 kg) Reusable power cords, trocars Follow manufacturer’s instructions; 24 hours at 20-29°C Fabric 3.0 lbs (1.4 kg) Reusable cloth gowns, towels Follow manufacturer’s instructions; 24 hours at 20-29°C. Reusable medical devices must be aerated following the instructions of device manufacturers and packaging material manufacturers, then released for use after sterilization based on successful inactivation of an EZTest®- Gas Biological Indicator in the Anprolene SteriTest process challenge device.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 28, 2026