510(k)K170540

FDA DEVICE FACTS

DM-Density

Densitas, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

AI/ML
DECISION DATEFebruary 23, 2018PRODUCT CODELLZCLINICAL AREARadiology

Indications for use

DM-Density is a software application intended for use with compatible full field digital mammography systems. DM- Density calculates percent breast density defined as the ratio of fibroglandular tissue to total breast area estimates. DM-Density provides these numerical M-Vu Breast Density is a software application intended for use with digital mammography systems. M-Vu Breast Density calculates breast density as a ratio of fibroglandular tissue and total breast area estimates. M-Vu Breast Density provides these numerical values for each N/A DENSITAS, INC. Traditional 510(k) Premarket Submission DM-DENSITY Section 5 values for each breast as well as a density category to aid interpreting physicians in the assessment of breast tissue composition. DM-Density produces adjunctive information. It is not a diagnostic aid. breast as well as a density category to aid radiologists in the assessment of breast tissue composition. M-Vu Breast Density produces adjunctive information. It is not an interpretive or diagnostic aid. Patient Population Symptomatic and asymptomatic women undergoing mammography Same N/A End Users Interpreting Physicians Same N/A Image Source Modalities

Hologic Selenia Dimensions All digital radiography (DR) systems and computed radiography (CR) systems N/A – Suite of image source modalities that are compatible with iReveal include the source modalities compatible with DM- Density. Hologic Lorad Selenia

Input: Image Data Format DICOM full field digital mammography imager – For Presentation; RCC, LCC, RMLO, LMLO DICOM digital mammography imager – For Processing; RCC, LCC, RMLO, LMLO DM-Density = For Presentation; iReveal = For Processing Output Data BI-RADS 4th Ed. For each breast:

● Area of fibroglandular tissue (cm²)

● Area of breast (cm²)

● Area-based breast density (%) For each patient: DM-Density breast density grade and percent breast density

BI-RADS 5th Ed. For each patient: DM-Density breast density grade

For each breast:

● Area of fibroglandular tissue (cm²)

● Area of breast (cm²)

● Area-based breast density (%) For each patient:

VuCOMP density grade/BIRADS breast density Subject device provides breast density grade consistent with BI- RADS 5th Ed.; Predicate device does not conform to the 5th Ed. scale. DENSITAS, INC. Traditional 510(k) Premarket Submission DM-DENSITY Section 5 Measurement Scales 4-category breast density scale from 4th Ed. ACR BI-RADS Atlas 2003 4-category breast density scale from 4th Ed. ACR BI-RADS Atlas 2003 Subject device provides users with the option of utilizing either the 4th or 5th edition scales;

See the full product information製品情報をすべて見るには