FDA DEVICE FACTS
BD FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 and 4-3-3 optical configurations), BD FACSuite Clinical Software, BD Multitest 6-Color Assays, BD Multitest 4-Color Assays, BD Multitest 6-Color TBNK
Becton, Dickinson and Company
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
BD Multi-Check Control is intended as a complete process control for immunophenotyping by flow cytometry. It is a control for antibody staining, red blood cell (RBC) lysis, instrument setup and performance, and data analysis on BD FACSLyric, BD FACSCanto II, BD FACSCanto, and BD FACSCalibur flow cytometers. Whole Blood Flow Control (WBFC) is a stabilized preparation of human peripheral leukocytes and erythrocytes to be used as a control in the complete immunophenotyping process which includes: antibody staining, RBC lysis, instrument set-up and instrument performance. Multi-Check CD4 Low Control BD Multi-Check CD4 Low Control is intended as a complete process control for immunophenotyping by flow cytometry. It is a control for antibody staining, red blood cell (RBC) lysis, instrument setup and performance, and data analysis on BD FACSLyric, BD FACSCanto II, BD FACSCanto, and BD FACSCalibur flow cytometers. StatusFlowLo is intended as a complete process control for immunophenotyping by flow cytometry. It is a control for antibody staining, RBC lysis, instrument set-up, instrument performance and data analysis. BD Biosciences Premarket Notification Page 18-17 of 24 BD FACSLyric Flow Cytometer A summary of the comparison is included as follows:
The subject device is similar to the predicate device as follows: Used for identification and enumeration of human lymphocyte cell subsets Performs the same flow cytometric assays with the same Multitest reagents and the same process controls Uses the same Trucount Tubes with a known number of beads per sample volume to calculate absolute cell counts Based on multicolor fluorescence Uses red, blue and violet lasers to provide excitation illumination for the specific wavelengths of the fluorophores; only the red and blue are used in the Multitest assays. Uses dichroic mirrors to split fluorescence emissions into wavelength ranges for each fluorophore to be detected Uses photomultiplier tubes (PMTs) for the detection of fluorescence emission signal The subject device differs from the predicate device as follows: Is available in four optical configurations: 3-1, 4-2, 4-2-2, and 4-3-3, whereas the Predicate Device is available in 3 optical configurations: 4-2, 4-2-2 and 5-3. Has a high powered red laser that yields higher detection sensitivity compared to the predicate device Instrument QC is performed using CS&T Beads and fluorescence compensation is established by using FC beads 7-color kit, whereas for the predicate device, FACS 7-color setup beads are used to adjust fluorescent detector voltages, to set fluorescence compensation, and to monitor daily instrument performance. The subject device measures more parameters and is capable of more accurately assessing the instrument performance. Uses the optional FACS Universal Loader to automate loading tubes in 30- or 40-tube rack, whereas the predicate device uses FACS Loader which accommodates up to 40 tubes in a carousel. Smaller footprint with no separate wet cart for fluidics and generates much lower noise output than the predicate device. BD Biosciences Premarket Notification Page 18-18 of 24 BD FACSLyric Flow Cytometer
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。