510(k)K171367

FDA DEVICE FACTS

SANCARE STERILE LATEX EXAMINATION GLOVES (also marketed as GLOVTEK STERILE LATEX EXAMINATION GLOVES)

Sanrea Healthcare Products Pvt, Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJanuary 26, 2018PRODUCT CODELYY

Indications for use

A Powder Free Patient Examination Glove is a Disposable Device made of Natural Rubber Latex and is intended to be worn on the hands, for medical purposes to provide a barrier against potentially infectious materials and other contaminants. The Sterile Latex Patient Examination gloves, Powder Free is a disposable device intended for medical purposes that is worn on the examiners hand or finger to prevent contamination between patient and examiner Similar

Description Sterile Powder Free, Patient Examination gloves made of natural rubber latex. The gloves are provided in Sizes Extra Small, Small, Medium, Large and Extra Large Sterile Powder Free, Patient Examination gloves made of natural rubber latex. The gloves are provided in Sizes Extra Small, Small, Medium, Large and Extra Large Similar

Presentation Sterile gloves are provided in pouches Sterile gloves are provided in pouches Identical

Material Natural Rubber Latex Natural Rubber Latex Identical Product code LYY LYY Identical Non-sterile or sterile Sterile Sterile Identical

Single Use Yes Yes Identical Ambidextrous Yes Yes Identical

Dimensions Meets ASTM D3578 Meets ASTMD3578 - Overall length min 230 mm, width varies from 70 mm for XS size to 120 mm for XL size, thickness in cuff, finger and palm has a minimum 0.08 mm Identical

Tensile Strength Meets ASTM D 3578and ASTM D412, D573

Meets ASTM D 3578 and ASTM D412, D573 - Tensile strength 18 Mpa min for before aging and 14 Mpa min for after aging Aging done at 70 ±2 deg C for 166±2 hrs or 100±2deg C for 22±0.3 hrs Identical

Ultimate Elongation Meets ASTM D 3578 Meets ASTM D 3578 Ultimate elongation 650 % min for before aging and 500 % min for after aging. Aging done at 70 ±2 deg C for 166±2 hrs or 100±2 deg C for 22±0.3 hrs Identical Stress at 500% Elongation Meets ASTM D 3578 Meets ASTM D3578 - Stress at 500% Elongation for before aging is 5.5Mpa (max) Identical Freedom from pinholes Meets ASTM D 5151 and ASTM D3578 Meets ASTM D 5151 and ASTM D3578 Identical

Meets ASTM D 6124 Identical Residual Powder Meets ASTM D 6124 Less than 2 mg per glove Residual Protein Meets ASTM D 5712 Meets ASTM D 57 12 – Less than 50µg/dm² Identical Non-irritant – Primary Skin Irritation In Rabbits Under the conditions of the study the device is not an irritant Identical

Biocompatibility Tests

ISO 10993-10 Non-sensitizer – Skin Sensitization in Guinea pigs Under the conditions of the study the device is not a sensitizer Identical Sterility Ethylene Oxide sterilized Ethylene Oxide sterilized Identical

Labeling * Powder Free * Latex patient exam glove * Sterile * Single use only * Ambidextrous * Manufactured for * Lot No * Intended use * Quantity * Country of origin *Powder Free *Latex Patient exam glove *Sterile *Single use only *Ambidextrous *Manufactured for *Lot No *Intended use *Quantity *Country of origin Identical

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 28, 2026