FDA DEVICE FACTS
Single Lumen Ovum Aspiration Needles
Willian A. Cook Australia Pty, Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Single Lumen Ovum Aspiration Needles are used for laparoscopic or ultrasound guided transvaginal aspiration and flushing of oocytes from ovarian follicles for patients undergoing Assisted Reproductive procedures. COMPARISON OF INTENDED USE AND TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICE: Single Lumen Ovum Aspiration Needles have similar Indications for Use as the predicate device (K983593). The intended use of the subject device is the same as the predicate device. The Single Lumen Ovum Aspiration Needles are a modification of the Ovum Pick-up Aspiration Needles (K983593). The modifications are: The indications for use statement has been modified from the predicate device to include transvaginal ultrasound and laparoscopic approaches, both of which were specifically stated within cleared labeling for the legally marketed device. This modification to the Indication for Use statement does not impact safety and effectiveness of the device. Addition of a 21-gauge variant to the K-OPS Series needles. This modification provides a smaller gauge needle option. The 21-gauge variant has a 4 Fr aspiration tubing. Product codes Needle gauge Needle length (cm) Aspiration Line (cm) Vacuum Line (cm) Flushing Line (cm) Bevel Type K-OPAA-series 17, 18, 20 35 n/a n/a n/a B K-DOPU-series 17 28 or 35 60 or 90 n/a n/a B K-OPS-series 16, 17, 19, 20, or 21 28, 30, 33, or 35 60 or 90 n/a n/a A or B K-OSN-series 16 or 17 25, 30, 33, or 35 60 or 90 50 n/a A or B K-IOPS-series 20 35 60 50 n/a A K-UCI-series 16 or 17 30 or 35 60 n/a 60 A Premarket Notifications Submission – Special 510(k) Single Lumen Ovum Aspiration Needles William A. Cook Australia Pty Ltd Addition of a 17 gauge, 30 cm guide needle. This m odification provides a guide needle size suitable for the 20-gauge K-IOPS variant. The aspiration and flushing tubing has changed from Tetrafluoroethylene (NRT [TFE]) to Fluorinated Ethylene Propylene (NRT-FEP) and Polytetrafluoroethylene (NRT-PTFE). The modifications listed above do not raise different questions of safety and effectiveness as compared to the predicate device.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。