DECISION DATEMay 8, 2018PRODUCT CODEHRS

Indications for use

The Trident Extremity Fixation System consisting of plates and screws are intended for use in stabilization and fixation of fresh fractures, revision procedures, joint fusion and reconstruction of bone of the feet, hand, ankle and toes. Specific examples include:

- Arthrodesis of the first metatarsalcuneiform joint (Lapidus fusion procedure)

- Arthrodesis of the first metatarsalphalangeal joint (MTP fusion procedure)

- Primary and revision MTP fusion due to hallux rigidus and/or hallux valgus corrections

- Revision of failed first MTP arthroplasty implant 2nd, 3rd and 4th metatarsal weil osteotomy correction indications

- Metatarsal osteotomies to correct hallux valgus bunion indications

- Fractures of the fifth metatarsal bone in the foot

- Carpal bone fusions and fractures Flatfoot Osteotomies:

- Lateral column lengthening (Evans osteotomy)

- Plantar flexion opening wedge osteotomy of the medial cuneiform (Cotton osteotomy)

- Medial displacement calcaneal osteotomy Midfoot/Hindfoot Arthrodesis/Fusions

- Lisfranc arthrodesis and/or stabilization

- 1st, 2nd, 3rd and 4th Tarsometatarsal (TMT) fusions

- Navicular-Cuneiform (NC) joint fusions

- Talo-Navicular (TN) joint fusions

- Calcaneo-Cuboid (CC) joint fusions

- Medial column fusions (NC and 1st TMT) The Trident Extremity Fixation System screws and plates are indicated for use with the Trident Plates and Screws of the same material. The locking and non-locking solid cortical screws, cannulated screws and headless screws are also indicated for bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair and fracture fixation, appropriate for the size of the device.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 27, 2026