sterEOS Workstation

Eos Imaging

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJune 19, 2018PRODUCT CODELLZ

Indications for use

Complete original indications for use

The sterEOS Workstation is intended for use in the fields of musculoskeletal radiology and orthopedics in both pediatric and adult populations as a general device for acceptance, transfer, display, storage, and digital processing of 2D X- ray images of the musculoskeletal system including interactive 2D measurement tools. When using 2D X-ray images obtained with the EOS Imaging EOS System , the sterEOS Workstation provides interactive 3D measurement tools:

• To aid in the analysis of scoliosis and related disorders and deformities of the spine in adult patients as well as pediatric patients. The 3D measurement tools include interactive analysis based eit her on identification of anatomical landmarks for postural assessment, or on a model of bone structures derived from an a priori image data set from 175 patients (91 normal patients, 47 patients with moderate idiopathic scoliosis and 37 patients with severe idiopathic scoliosis), and dry isolated vertebrae data for spine modeling. The model of bone structure s is not intended for use to assess individual vertebral abnormalities and is indicated only for patients 7 years and older. For postural asse ssment, a set of comparative tools is provided allowing the comparison of perfor med measurements to reference values for patients over 18 years old.

• To aid in the analysis of lower limbs alignment and related disorders and deformities based on angle and length measurements. The 3D measurement tools include interactive analysis based either on identification of lower limb alignment landmarks or as for the spine, on a model of bone structures derived from an a priori im age data set. The model of bone structures is not intended fo r use to assess individual bone abnormalities. The 3D package including model-based measur ements and torsion angles is indicated only for patients 15 years or older. Only the 2D/3D ruler is indicated for measurements in patients younger than 15 years old.

See the full product information製品情報をすべて見るには