510(k)K172347

FDA DEVICE FACTS

GMK Hinge, GMK Revision

Medacta International S.A.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATENovember 1, 2017PRODUCT CODEKRO

Indications for use

The GMK HINGE knee prosthesis is designed for cemented use in total knee arthroplasty when the preoperative diagnosis of the joint determines that the bone and stability situation require the implantation of a constrained prosthesis. The GMK HINGE knee system is indicated in the following cases:

• Severely painful and/or disabled joint as a result of arthritis, traumatic arthritis, rheumatoid arthritis or polyarthritis associated with bone loss and/or severe joint instability  Considerable loss of function of the knee joint  High-grade joint destruction requiring additional stabilization with stems and reconstruction of bone defects with metal augmentation  Failure of a primary prosthesis (e.g. infection, loosening)  Former revision arthroplasty  Post traumatic loss of joint configuration  Avascular necrosis of femoral condyle Tibial augmentations are to be screwed to the tibial baseplate with both of the two provided fixing screws. When a GMK HINGE implant is used it is mandatory to implant both the femoral and tibial components with an extension stem. The Evolis/GMK knee prosthesis is designed for cemented use in total knee arthroplasty, if there is evidence of sufficient sound bone to seat and support the components. This knee replacement system is indicated in the following cases:  Severely painful and/or disabled joint as a result of arthritis, traumatic arthritis, rheumatoid arthritis, or polyarthritis  Avascular necrosis of femoral condyle  Post traumatic loss of joint configuration  Primary implantation failure Tibial wedges cemented are to be attached to the tibial baseplate with both the fixing cylinders and bone cement. The screwed tibial augments are for screwed fixation to the tibial baseplate. In case a semi-constrained liner is used, an extension stem must be implanted both on the tibial and on the femoral components. In case a GMK Revision tibial tray is used, an extension stem must be implanted.

See the full product information製品情報をすべて見るには