SterilContainer with PrimeLine Pro Lid
Aesculap, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Aesculap Sterilcontainer System is a reusable sterilization container system (consisting of solid & perforated bottoms, a perforated lid w/ filter retention plates, and reusable polytetrafluoroethylene (PTFE) filters) intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device until used. This container system is compatible for use in pre-vacuum steam and IUSS (Immediate Use Steam Sterilization) sterilization modalities. The SterilContainer System for includes accessories such as silicone mats, baskets, trays, and racks. Table 1: Steam and IUSS Compatible SterilContainer with PrimeLine Pro Lid Acombined maximum load validated for all container configurations is 25lbs. Sterilization Cycle Parameters PrimeLime Pro Container | Solid Base to be used | Max No. of Lumens Lid with JP050 — Lid Size_| with Lid Lumen Configuration Immediate Use (Non porous) % size Lid JK340 (4-1/4 in height) Immediate Use — Non Porous: 270°F Temp, 3 min. Exposure (298 x281 x36) JK341 (5-1/2 in height) No lumens, a hinged device, No stacking recommended Art. No. JP121 — JP125 JK342 (6 in height) and a knurled (irregular JK344 (8 in height) surface) device. Immediate Use (porous) JK346 (10-1/2 in height) 270°F Temp, 4 min. Exposure % size Lid JK740 (4-1/4 in height) Immediate Use — Porous: No stacking recommended (465 x 281 x 36) JK741 (5-1/2 in height) 1 SS lumen with 3mm I.D. x Art. No. JP111 — JP115 JK742 (6 in height) 400mm L and a hinged device. JK744 (8 in height) Prevacuum Dry Time Study Full size Lid JK440 (4-1/4 in height) 270°FTemp, 4min.Exposure, 30 min. (588 x 281 x 36) JK441 (5-1./2 in height) Dry Time Art. No. JP101 — JP105 JK442 (6 in height) Stacking should not exceed 16-18” JK444 (8 in height) height JK446 (10-1/2 in height) Sterilization Cycle Lid Size Perforated Base to be used with Lid % size Lid JN340 (41/2 in height) (298 x281 x36) JN341 (51/2 in height) Prevacuum Dry Time Study Art. No. JP121 — JP125 JN342 (6 in height) 270°FTemp, 4min.Exposure, 30 min. JN344 (8 in height) Dry Time JN346 (101/2 in height) Stacking should not exceed 16-18” ¥%, size Lid JN740 (4-1/4 in height) height (465 x 281 x 36) JN741 (5-1/2 in height) Art. No. JP111 — JP115 JN742 (6 in height) JN744 (8 in height) Full size Lid JN440 (4-1/4 in height) (588 x 281 x 36) JN441 (5-1/2 in height) Art. No. JP101 — JP105 JN442 (6 in height) JN444 (8 in height) JN446 (10-1/2 in height) Table 2: Steam and IUSS Cycle Compatible Accessories Accessories Steam and IUSS Stainless Steel baskets, Yes basket lids, and dividers Instrument Organization System (Silicone and Stainless Steel racks, Yes brackets, holders, and clamps) Silicone mats Yes Stainless Steel racks, trays, holders, clamps, brackets, and platforms Yes
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。