Discovery XR656 HD
Ge Hualun Medical Systems Co. , Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Discovery XR656 HD is intended to generate digital radiographic images of the skull, spinal column, chest, abdomen, extremities, and other body parts in patients of all ages. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position and the system is intended for use in all routine radiography exams. Optional image pasting function enables the operator to stitch sequentially acquired radiographs into a single image. The device is not intended for mammographic applications. Technology: The Discovery XR656 HD employs the same fundamental scientific technology as its predicate device. The intended use and patient populations are the same between Discovery XR656 HD and predicate device. The indication for use is the same except that GE Healthcare Discovery XR656 HD does not include the Dual Energy advanced application that is provided with the predicate device. The Discovery XR656 HD did not change system software architecture, operator I/F, Tube, or generator. It does incorporate the same 6-axis Overhead Tube Suspension (OTS) and Overhead Bridge that enables the automatic positioning feature and image pasting technique from the referenced Discovery XR656 (K132261), but does not include the VolumeRad indication from this referenced device. The difference being introduced with the Discovery XR656 HD is that exposures can be captured with cleared detectors of multiple sizes. These cleared detectors utilize WiFi (802.11) instead of Ultra Wideband (UWB) technology to transfer the image to the system. To accommodate the cleared wireless detectors, the Discovery XR656 HD changed the following from the predicate device:
• Wireless communication hardware for detector communication was changed from UWB to WiFi (802.11)
• Elevating Table and Wallstand Detector Housing geometry and its associated detector charging hardware and firmware to accommodate the 17 inch x 14 inch cleared wireless detectors
• System software to accomplish the following: o WiFi (802.11) association and pairing with the cleared wireless detectors o Synchronizing the image acquisition and image retrieval from the cleared wireless detectors o Image processing algorithms to accommodate multiple image matrix sizes
• User interface updates for image acquisition to incorporate the cleared wireless detectors into the user workflow Determination of
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。