FDA DEVICE FACTS
Surgical gown (AE1001, AE2001, AE3001); Surgical Gown (AG1001, AG2001, AG3001)
Gmax Industries, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Surgical gown is intended to be worn by operating room personnel during surgical procedure to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material.
Per ANSI/AAMI PB70:2012 Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities, the AE series surgical gowns met the requirements for Level 2 classification, the AG series surgical gowns met the requirements for Level 3 classification. Medline Disposable EclipseTM Surgical Gowns are surgical apparel that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of body fluids, micro -organisms, and particulate material. Disposable Surgical Gowns, which are blue colored and EO sterilized, are indicated to be worn by operating room personnel during surgical procedures to protect both the s urgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. It culd achieve Level 3 Barrier Performance as per AAMI PB70:2003. It is for single use only. Similar Style Non-reinforced/ Fabric-reinforced/ Poly-reinforced Non-reinforced/ Fabric-reinforced/ Poly-reinforced Reinforced Same Size XL L, XL,XXL M, L, XL, XXL See note below Difference 1 Physical specification Barrier protection level Level 2/Level 3 per AAMI PB70 Level 2 per AAMI PB70 Level 3 per AAMI PB70 Same Tearing strength >30N Not known Not known See note below Difference 2 Fire protection Class I Not known Class I Same Lint: Log10< 4 Not known Not known See note below Difference 3 Air Permeability >30 ft3/min/ft2 Not known Not known Mechanical specifications Tensile strength ≥20N Not known ≥20N Same Durability Disposable Disposable Disposable Same Material SMMMS, Polypropylene, PE (Poly Ethylene), Polyester SMS SMS, SPP, Polypropylene, PE, Nylon, Polyester See note below Difference 4 Biocompatibility Under the conditions of the study, the device is non -toxic, Under the conditions of the study, the device is non -toxic, Under the conditions of the study, the device is non -toxic, Same non-irritating, and non-sensitizing. non-irritating, and non-sensitizing. non-irritating, and non-sensitizing.
Difference 1 The subject devices only have one size of XL, while the predicate device 1 has three kinds of sizes which are L, XL, XXL, and the predicate device 2 has four kinds of device which are M, L, XL, XXL. The difference in the size will not affect the function. So the difference in t he size will not affect the safety and effectiveness of the subject device.
Difference 2 Although the tearing strength of th e predicate devices are unknow n, the tearing strength of the subject device is large enough for safety using. Therefore this different will not raise new safety and effectiveness questions.
Difference 3 Although the linting level of the predicate devices are unknow n, the linting level of the subject device is acceptable for safety using. Therefore this different will not raise new safety and effectiveness questions.
Difference 4 The main material of the subject device is SMMMS, and the main material of th e Predicate Device 1 and Predicate Device 2 is SMS, the difference between the material of the subject device and predicate devices is the amounts of the meltblown layers. Therefore, this difference will not affect the substantially equivalency of the subject device.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。