Pulse Oximeter
Shenzhen Imdk Medical Technology Co., Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Fingertip Pulse Oximeter C101H1 is a non-invasive device intended for spot checking of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR). This portable device is indicated for use in adult patients in hospitals. Fingertip Pulse Oximeter A310 is a non-invasive device intended for spot checking of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR). This portable device is indicated for use in adult patients in hospitals Principle The device displays numerical values for functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate by measuring the absorption of red and infrared (IR) light passing through perfused tissue. Changes in the absorption caused by the pulsation of blood in the vascular The device displays numerical values for functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate by measuring the absorption of red and infrared (IR) light passing through perfused tissue. Changes in the absorption caused by the pulsation of blood in the vascular Comparison Items Proposed device: C101H1 Predicate device: A310 (K153021) bed are used to determine oxygen saturation and pulse rate. bed are used to determine oxygen saturation and pulse rate. Specification LED wavelength Red= 660 nm; Infrared=904nm Red= 660 nm; Infrared=905nm Power source 2 AAA alkaline batteries. 2 AAA alkaline batteries. Display data SpO2%; PR SpO2%; PR SpO2 Measuring Range 0%-100% 0%-100% SpO2 Resolution 1% 1% SpO2 Accuracy 70~100%, ±3%; 70~100%, ±3%; 0-69%, unspecified; PR Measuring Range 30-240BPM. 30-235BPM. PR Resolution 1 bpm 1 bpm PR Accuracy ±1 bpm or ±1%, whichever is greater ±2 bpm (30-99bmp) ±1% (100-235bmp) Testing Biocompatibility ISO 10993-5 and ISO 10993-10 ISO 10993-5 and ISO 10993-10 Electrical Safety IEC 60601-1 IEC 60601-1-11 IEC 60601-1 IEC 60601-1-11 Electromagnetic Compatibility IEC 60601-1-2 IEC 60601-1-2 Performance ISO 80601-2-61 ISO 80601-2-61
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。