FDA DEVICE FACTS
Amsco Evolution Medium Steam Sterilizer
STERIS Corporation
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
T he Amsco Evolution Medium Steam Sterilizer models HC-600 and HC-1500 are designed for sterilization of heat and moisture-stabile materials used in healthcare facilities and are available in two configurations:
• Prevacuum – is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.
• Steam Flush Pressure-Pulse (SFPP) – is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. T he Amsco Evolution Medium Prevacuum Steam Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 6-1): Table 6-1. Amsco Evolution Medium Prevacuum Steam Sterilizer factory-programmed Sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Fabric Packs. Refer to Table 6-3 for recommended quantities. Prevac 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 6-3 for recommended quantities. Liquid* 250°F (121°C) 45 minutes N/A Refer to Table 6-4 for recommended quantities. Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 250°F (121°C) 30 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 270°F (132°C) 25 minutes 15 minutes Fabric Packs. Refer to Table 6-3 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A *The liquid cycle is for non-patient contact use only. The Amsco Evolution Medium Steam Flush Pressure-Pulse (SFPP) Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 6-2): Table 6-2. Amsco Evolution Medium Steam Flush Pressure-Pulse (SFPP) Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load SFPP 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Fabric Packs. Refer to Table 6-3 for recommended quantities. SFPP 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Fabric Packs. Refer to Table 6-3 for recommended quantities. Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 6-3 for recommended quantities. SFPP 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Liquid* 250°F (121°C) 45 minutes N/A Refer to Table 6-4 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A *The liquid cycle is for non-patient contact use only. The following table (Table 6-3) lists STERIS’s recommended loads by sterilizer size: Table 6-3. Amsco Evolution Medium Steam Sterilizer recommended loads Sterilizer Size Model Number Wrapped Instrument Trays Fabric Packs 26” x 26” x 39” HC-600 9 12 26” x 37 ½” x 60” HC-1500 20 36 T he following table (Table 6-4) provides a guideline for liquid cycle processing. The liquid cycle is for non-patient contact use only. T able 6-4. Amsco Evolution Medium Steam Sterilizer liquid cycle processing guideline Number of Containers Volume of Liquid In One Container Minimum Recommended Sterilize Time at 250ºF (121ºC) 3 1000 ml 45 minutes T he Amsco Evolution Medium Steam Sterilizer is offered in the following chamber sizes:
• Model HC-600 26” x 26” x 39” (660 mm x 660 mm x 991 mm)
• Model HC-1500 26” x 37½” x 60” (660mm x 950mm x 1524mm)
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。