RARA CRAFT DATABASE for FDA Medical Devices
510(k)K180139

FDA DEVICE FACTS

Safe Secure Sterilization Pouches and Rolls

Safe Secure Packing Co., Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJanuary 3, 2019PRODUCT CODEFRG

Indications for use

Safe Secure Sterilization Pouches and Rolls are intended to be used to enclose another medical device, in a single or double pouch configuration, that is to be sterilized by a health care provider using: * Gravity steam at 121°C (250°F) for 30 minutes; 25 minutes dry time ¢ Pre-vacuum steam at 132°C (270°F) for 4 minutes; 20 minutes dry time « Pre-vacuum steam at 134°C (273°F) for 3 minutes; 20 minutes dry time ¢ Pre-vacuum steam at 135°C (275°F) for 3 minutes; 16 minutes dry time ¢ Ethylene Oxide (EO) with a concentration of 735 mg/L at 55°C (131°F) and 50% to 80% relative humidity for 60 minutes. Aeration time of 8 hours at 600C (140oF). * The recommended hydrogen peroxide vapor sterilization cycle is the STERRAD® 100S Short Cycle. The steam and EO device is not intended and has not been validated for sterilization of devices that contain lumens. The hydrogen peroxide device has been validated for devices that contain a lumen. The hydrogen peroxide device has been validated for devices that contain a lumen; the 100S has been validated for medical devices with a single stainless steel lumen with an inside diameter of >1mm and an length of <125mm as well as lumens with an inside diameter >2mm and a length of <250mm only. The external chemical indicators on the pouches/rolls are intended to demonstrate that the device has been exposed to the steam. EO, or hydrogen peroxide sterilization process and to distinguish between processed and unprocessed devices. The chemical indicators change from green to purple after exposure to steam, from yellow to brown after exposure to ethylene oxide, and from blue to pink for hydrogen peroxide. The Tyvek version of the pouch is for EO and hydrogen peroxide sterilization only. If stored according to the recommended conditions, the products before sterilization have a maximum shelf life of 2 years from the date of manufacture. The pouches are intended to allow sterilization of the enclosed medical device(s) and also to maintain sterility (SAL=10-6). The subject device is intended and has been validated to maintain sterility of the enclosed devices for 6 months after steam sterilization, 24 months after EO sterilization (for paper pouch), two years after hydrogen peroxide sterilization and five years for EO sterilization (for Tyvek Pouch). The maximum validated pouch load is 2.64 pounds (1.2kg).

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 26, 2026