RARA CRAFT DATABASE for FDA Medical Devices
510(k)K181865

FDA DEVICE FACTS

Acu-sInQ Complete Endoscope Cleaning Aid System

STERIS Corporation

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 14, 2018PRODUCT CODEFEB

Indications for use

The Acu-sInQ Complete Endoscope Cleaning Aid System is intended to assist manual flexible endoscope cleaning according to the instructions provided by the endoscope manufacturer, by facilitating performance of a leak test, accurate detergent dosing with water temperature monitoring, channel flushing, rinsing, and process documentation. The Fluid pump CP #3 is intended to pump fluid media thru the channels of endoscope and accessories with lumens. The various fluid media that are compatible are soapy water, enzyme/water solution, water, 70% alcohol, and liquid disinfectants. The pump will also pump minimal amounts of air to help purge the channels or lumens of droplets of fluid media. Consult with instrument manufacturer for fluid media compatibility. Both devices are intended to flush fluid through the channel of an endoscope to aid in the manual cleaning process. The subject device has the added functionality to assist the user with additional steps of the endoscope cleaning process, leak test, detergent dosing and temperature monitoring. Acu-sInQ Complete Endoscope Cleaning Aid System

November 9, 2018 Feature Acu-sInQ Complete Endoscope Cleaning Aid (proposed) Fluid Pump CP-3 Predicate (K914524) Comparison Operating Principles/ Technology A microprocessor controlled unit operates internal pumps to aid in the cleaning of endoscopes. An internal air pump pressurizes an endoscope through a dedicated leak test tubing to perform a leak test. A detergent tube is placed in a container of detergent and a peristaltic pump pulls the detergent through the tubing, the detergent is then expelled through a discharge tube into the cleaning solution. A tubing set pulls fluid from the cleaning solution through a peristaltic pump and discharge tubing set where it is expelled through the endoscope channels. Flushing fluids are placed into a container, pre-cleaning basin or sink. A tubing set pulls fluid from the container, basin, or sink into and through an internal fluid pump. The fluid is then expelled from the pumps through discharge tubing sets which are connected to the endoscope channels. The fluid is then pumped through the endoscope channels. Both devices utilize electronically controlled flush pumps to flush fluid through the channels of an endoscope. The

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 26, 2026