FDA DEVICE FACTS
Wondfo T-Cup Multi-Drug Urine Test Cup
Guangzhou Wondfo Biotech Co., Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Complete original indications for use
Wondfo T-Cup® Multi-Drug Urine Test Cup tests are competitive binding, lateral flow immunochromatographic assays for qualitative and simultaneous detection of Amphetamine, Buprenorphine, Secobarbital, Oxazepam, Cocaine, 2- ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, Methamphetamine, Methylenedioxymethamphetamine, Morphine, Methadone, Oxycodone, Phencyclidine, Propoxyphene, Nortriptyline and Cannabinoids in human urine at the cutoff concentrations of: Drug (Identifier) Cut-off level Amphetamine (AMP) 1000 ng/mL or 500 ng/mL Buprenorphine (BUP) 10 ng/mL Secobarbital (BAR) 300 ng/mL Oxazepam (BZO) 300 ng/mL Cocaine (COC) 300 ng/mL or 150 ng/mL 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) 300 ng/mL Methamphetamine (MET) 1000 ng/mL or 500 ng/mL Methylenedioxymethamphetamine (MDMA) 500 ng/mL Morphine (MOP 300/OPI 2000) 2000 ng/mL or 300 ng/mL Methadone (MTD) 300 ng/mL Oxycodone (OXY) 100 ng/mL Phencyclidine (PCP) 25 ng/mL Propoxyphene (PPX) 300 ng/mL Nortriptyline (TCA) 1000 ng/mL Cannabinoids (THC 50) 50 ng/mL Wondfo T-Cup® Multi-Drug Urine Test Cup offers any combinations from 2 to 15 drugs of abuse tests but only one cutoff concentration under same drug condition will be included per device. It is for in vitro diagnostic use only. The tests may yield positive results for the prescription drugs Buprenorphine, Nortriptyline, Oxazepam, Secobarbital, Propoxyphene, and Oxycodone when taken at or above prescribed doses. It is not intended to distinguish between prescription use or abuse of these drugs. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly in evaluating a preliminary positive result. The tests provide only preliminary results. To obtain a confirmed analytical result, a more specific alternate chemical method must be used. GC/MS or LC/MS is the recommended confirmatory method.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。