FDA DEVICE FACTS
JTL-250-01
Jointechlabs, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The JTL Tissue Processing Device is a sterile medical device intended for the processing of lipoaspirate tissue in medical procedures involving the harvesting, concentrating and transferring of autologous adipose tissue harvested with a legally marketed lipoplasty system. The device is intended for use in the following surgical specialties when the transfer of harvested adipose tissue is desired: orthopedic surgery, arthroscopic surgery, neurosurgery, gastrointestinal and affiliated organ surgery, urological surgery, general surgery, gynecological surgery, thoracic surgery, laparoscopic surgery, and plastic and reconstructive surgery when aesthetic body contouring is desired. Only legally marketed accessory items, such as syringes, should be used with the system. If harvested fat is to be re- implanted, the harvested fat is only to be used without any additional manipulation. The Lipogems System is a sterile medical device intended for the closed-loop processing of lipoaspirate tissue in medical procedures involving the harvesting, concentrating and transferring of autologous adipose tissue harvested with a legally marketed lipoplasty system. The device is intended for use in the following surgical specialties when the transfer of harvested adipose tissue is desired: orthopedic surgery, arthroscopic surgery, neurosurgery, gastrointestinal and affiliated organ surgery, urological surgery, general surgery, gynecological surgery, thoracic surgery, laparoscopic surgery, and plastic and reconstructive surgery when aesthetic body contouring is desired. Only legally marketed accessory items, such as syringes, should be used with the system. If harvested fat is to be transferred, the harvested fat is only to be used without any additional manipulation. Intended Use To process lipoaspirate fat tissue intended for autologous homofunctional implant (lipofilling) To process lipoaspirate fat tissue intended for autologous homofunctional implant (lipofilling) Site of use Hospitals Hospitals
Technical Features K182732,
Components Pre-assembled centrifuge tube with filters for microfracturing of adipose tissue Pre-assembled cylinder containing filters and stainless steel beads for microfracturing of adipose tissue Syringes Tubing Waste Collection Bag System Concept Closed Loop Closed Loop Fill Volume Up to 120 mL of fat Up to 120 mL of fat Mechanics of Tissue Separation Action Filtering and microfracturing by spinning the tube in a centrifuge so that the material separates as it moves through various filters Filtering and microfracturing by physical shaking of the cylinder and then hanging the cylinder in reverse orientation so that the material moves through filters by gravity Provided Sterile Yes Yes Sterilizing agent Radiation Ethylene Oxide Sterility Assurance Level 10-6 10-6 Single Use Yes Yes Duration of use ≤ 24 hours ≤ 24 hours Tissue contact materials Compliant with ISO 10993 Compliant with ISO 10993
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status