RARA CRAFT DATABASE for FDA Medical Devices
510(k)K183063

FDA DEVICE FACTS

Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR Systems

Philips Medical Systems Nederland B.V.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEFebruary 14, 2019PRODUCT CODELNH

Indications for use

There are minor modifications to the indications for use statement for the proposed Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR S ystems for clarity, but the intended use has not changed. Philips Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device. This MR system enables trained physicians to obtain cross-secti onal images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation, representing the spatial distr ibution of protons or other nuclei with spin. Image appearance is determined by many different physical prope rties of the tissue and the anatomy, the MR scan technique applied, and presence of contrast agents. The use of contrast agents for diagnostic imaging applications should be performed consistent with the approved labeling for the contrast agent. Philips Medical Systems Nederland B.V. Magnetic Resonance Imaging Bundled Abbreviated 510(k)

Premarket Notification [510(k)] Submission S5 Philips Medical Systems Nederland B.V. Ingenia, Ingenia CX, Ingenia Elition, Ingenia Ambition MR Systems

The trained clinical user can adjust the MR scan parameters to customize image appearance, accelerate image acquisition, and synchronize with the patient’s breathing or cardiac cycle. The systems can use combinations of images to produce physical parameters, and related derived images. Images, sp ectra, and measurements of physical parameters, when interpreted by a trained physician, provide information that may assist diagnosis and therapy planning. The accuracy of determin ed physical parameters depends on system and scan parameters, and must be controlled and validated by the clinical user. In addition the Philips MR systems provide imaging capabilities , such as MR fluoroscopy, to guide and evaluate interventional and minimally invasive procedures in the head, body and extremities.

MR Interventional procedures, performed inside or adjacent to t he Philips MR system, must be performed with MR Conditional or MR Safe instru mentation as selected and evaluated by the clinical user for use with the sp ecific MR system configuration in the hospital. The appropriateness and use of i nformation from a Philips MR system for a specific interventional procedure and specific MR system configuration must be validated by the clinical user. Design Features/ Fundamental Scientific Technology: The proposed Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR Systems are based on the principle that certain atomic nuclei present in the human body will emit a weak relaxation signal when placed in a s trong magnetic field and excited by a radio signal at the precession frequency. The emitted relaxation signals are analyzed by the system and a computed ima ge reconstruction is displayed on a video screen. The principal technological components (magnet, transmit body coil, gradient coil, receive coils and patient support) of the proposed Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR Systems are identical to those used in the legally marketed predicate device Ingenia 1.5T, Ingenia 1.5T S, Ingenia 1.5T CX, Ingenia 3.0T, and Ingenia 3.0T CX R5.4 (K173079, 04/04/2018), and the legally marketed reference devices Ingenia Elition S and Ingenia Elitio n X (K173451, 3/20.2018) and the Ingenia Ambition S and Ingenia Ambition X (K 180479, 08/03/2018). The following are descriptions of the modified or minor enhanced software features. The main application of bFFE XD is to reduce banding artifacts, resulting from the B0 sensitivity of balanced Fast Field Echo (bFFE) sequences. Th ose black band artifacts can obscure information in the images. The main clinical application targeted by bFFE XD is high resolution 3D inner ear (auditory canal) imaging. IRIS ZOOM is an improvement of Zoom Diffusion Imaging in the spine. Due to the multi-shot capability, IRIS ZOOM delivers a higher resolution, lower distortion and improved fat suppression in spine when compared to Zoom Diffusion Imaging. Philips Medical Systems Nederland B.V. Magnetic Resonance Imaging Bundled Abbreviated 510(k)

Premarket Notification [510(k)] Submission S5 Philips Medical Systems Nederland B.V. Ingenia, Ingenia CX, Ingenia Elition, Ingenia Ambition MR Systems

MEGA is a feature that allows for detection of J-coupled metabolite signals like GABA (gamma-butyric acid) in the brain. MEGA is spectral editing technique and intended for single voxel 1H spectroscopy in the brain on 3T systems. SENC (Strain ENCoding) is intended for cardiac imaging, to measure c ardiac muscle contraction as a function of time within the cardiac cycle. SENC produces strain encoded images. Those images are processed by 3rd party software MyoStrain to produce strain analysis and reporting. The SyntAc (MDME) gives possibility to acquire Multi-Dynamic Multi-Echo (MDME) images. These images can be processed by 3 rd party (Synthetic MRI) software to produce the relevant radiological contrasts. VAPOR is an enhancement of the Philips Excitation implementation and is designed to be less sensitive to T1 variations and B1 inhomogeneities. sLASER is a modification of 1H SE (PRESS) localized spectroscopy and can be applied to Single Voxel Spectroscopy (SV) as well as Spectrosco pic Imaging (MRSI). The sLASER sequence uses slice selective adiabatic pairs of refocusing RF pulses to reduce the chemical shift displacement up to a facto r 4 when compared to PRESS-localized spectroscopy at 3T. Spiral Brain uses a spiral readout, which is applied as an alternative to th e Cartesian k-space traversal pattern. Some of the general benefi ts of spiral vs. Cartesian MRI include (1) faster scans, due to longer readout time and (2) image artifact robustness, due to reduced flow sensitivity). Spiral Brain leverages those benefits to enhance T1 SE sequences in the brain at 1.5T and 3T. 3D Non-selective excites the entire volume using a very short RF pulse in 3D FFE brain imaging. Due to the resulting shorter TR and shorter TE, 3D Non-selective delivers a faster protocol and improved grey-white matter contrast in 3D TFE. Diffusion XD TSE technique is an enhancement of Diffusion TSE. It introduces the SPLICE technique and enables the combination with a MultiVane readout. By allowing the combination with MultiVane, a multi-shot readout c an be achieved, which contributes to the sharpness of the resulting image and i ncludes intrinsic motion correction. 2KDTI is a technical enhancement of the maximal number of diffusion encodings that can be collected in one diffusion scan. 2KDTI provides up to 2048 independent diffusion encodings (vectors) with up to 1024 different weightings and 1024 different directions. Advanced diffusion gradient control allows the scientific user to select from multiple diffusion encoding gradient waveforms. Advanced diffusion gradient control enables the user to define manually the duration of the diffusion encoding gradients. k-t SENSE is a spatio-temporal acceleration technique that combines the benefits of k-t BLAST with the better image uniformity capabilities of S ENSE. Philips Medical Systems Nederland B.V. Magnetic Resonance Imaging Bundled Abbreviated 510(k)

Premarket Notification [510(k)] Submission S5 Philips Medical Systems Nederland B.V. Ingenia, Ingenia CX, Ingenia Elition, Ingenia Ambition MR Systems

Reconstruction-wise, the k-t BLAST works on a coil by coil basi s. k-t SENSE processes the coils (coil elements) integrally with the help of which the homogeneity of the images are enhanced. Cardiac ZOOM is a small FOV imaging technique which performs the excitation and refocussing pulses orthogonally. Cardiac ZOOM enhances black blood imaging, by providing accelerated and single beat imaging. This allows scanning of patients who cannot hold their breath. Retrospective cardiac gating synchronizes pulse sequence with cardiac rhythm so that cardiac motion related artifacts are removed. Retrospective gating is enhanced by allowing the combination with EPI and TFE-EPI seque nces, which are used to explore 4D flow imaging. Multiple echoes from an FFE scan can be summed to calculate a n ew image. mFFE Echo Summation automates this echo combination via a root-sum-of-squares echo summation in reconstruction SW. This delivers an e nhanced workflow when compared to the existing manual post-processing that is available in Image Algebra post-processing package. The Contrast Card enhancement offers the ability to add information on the contrast agent. After applying the contrast agent, which is done independent from the MR system, information on the applied contrast is added to the DICOM images. When viewing these images on the MR system the images, which have been taken while contrast was applied, are marked with an indication “Contrast”. After pressing Start Scan at the controls at the magnet façade the scan will automatically start (Autostart feature) when the RF door is closed. This function is the same as the legally marketed reference device Ingenia Elition S and Ingenia Elition X systems (K173451, 03/20/2018) and for the Ingenia Ambition S and Ingenia Ambition X systems (K180479, 08/03/2018) and is implemented without further changes. Based on the information provided above, the proposed Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR Systems do not raise different questions of safety and effectiveness compared to the legally marketed predicate device Ingenia 1.5T, Ingenia 1.5T S, Ingenia 1.5T CX, Ingenia 3 .0T, and Ingenia 3.0T CX R5.4 (K173079, 04/04/2018). Summary of Non- Clinical

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 25, 2026