SteriStay
Toul Meditech AB
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
V- PRO s2 Low Temperature Sterilization System The V-PRO® s2 Low Temperature Sterilization System using VAPROX® HC Sterilant is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices in Healthcare Facilities. The pre-programmed sterilization cycles operate at low pressure and low temperature, suitable for processing medical devices without leaving toxic residues.
Each Cycle can sterilize non-lumened instruments and instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors.
The V-PRO s2 Sterilizer Non Lumen Cycle can sterilize:‡ Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes. ‡ The validation studies were conducted using a validation load consisting of one instrument tray for a total weight of 25 lbs (11.3 kg).
The V-PRO s2 Sterilizer Fast Cycle can sterilize:‡ Medical devices (including single, dual and triple channeled rigid and semi-rigid endoscopes) with the following configurations:
• Single or dual channeled devices with stainless steel lumens that are ≥ 0.77 mm (~1/32”) internal diameter (ID) and ≤ 410 mm (~16-9/64”) in length ≥ 1.8 mm (~5/64”) ID x ≤ 542 mm (~21-5/16”) in length.
• Triple channeled devices with stainless steel lumens that are either: ≥ 1.2 mm (~3/64”) ID and ≤ 275 mm (~10-53/64”) in length ≥ 1.8 mm (~5/64”) ID and ≤ 310 mm (~12-13/64”) in length or ≥ 2.8 mm (~7/64”) ID and ≤ 317 (12-31/64”) mm in length
Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes. ‡ Validation testing for all lumen sizes was conducted using a maximum of eight (8) lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. Validation testing was conducted using a validation load consisting of one pouched instrument tray and two pouched devices outside of the tray with a total weight of 4.0 lbs (~1.8kg).
The V-PRO s2 Sterilizer Flexible Cycle can sterilize:@ One surgical flexible endoscope (such as those used in ENT, Urology and Surgical Care) or bronchoscope with light cord (if not integral to endoscope), mat, and additional load.
• The flexible endoscope may be a single or dual lumen device with lumens that are ≥ 1 mm (~3/64”) ID and ≤ 990 mm (38-63/64”) in length.
• Additional load, up to 11 lb (5 kg) can include stainless steel lumens with the following dimensions ≥ 0.76 mm (~1/32”) ID and ≤ 233 mm (~9 11/64”) in length ≥ 1.0 mm (~3/64”) ID and ≤ 254 mm (~10”) in length ≥ 1.8 mm (~5/64”) ID and ≤ 542 mm (~21 5/16”) in length @ The validation studies were conducted using a validation load consisting of two instrument trays. One tray contained one flexible endoscope, with silicone mat, instrument organizers and light cord (if not integral to scope), and the second tray contained additional load and twelve (12) stainless steel lumens for a total load weight of 11 lbs (5 kg). Hospital loads should not exceed the maximum number of lumens validated by this testing.
The V-PRO s2 Sterilizer Lumen Cycle can sterilize: ^ Medical devices (including single, dual and triple channeled rigid and semi-rigid endoscopes) with the following configurations:
• Single or dual channeled devices with stainless steel lumens that are ≥ 0.77 mm (~1/32”) ID and ≤ 410 mm (16-9/64”) in length and ≥ 1.8 mm (~5/64”) ID x ≤ 542 mm (~21-5/16”) in length.
• Triple channeled devices with stainless steel lumens that are either: ≥ 1.2 mm (~3/64”) ID and ≤ 275 mm (~10-53/64”) in length ≥ 1.8 mm (~5/64”) ID and ≤ 310 mm (~12-13/64”) in length or ≥ 2.8 mm (~7/64”) ID and ≤ 317 mm (12-31/64”) in length ^ Validation testing for all lumen sizes was conducted using a maximum of twelve (12) stainless steel lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of one instrument tray and two pouches for a total weight of 11 lbs (5.0 kg).
V- PRO 60 Low Temperature Sterilization System The V-PRO® 60 Low Temperature Sterilization System using VAPROX® HC Sterilant is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices in Healthcare Facilities. The pre-programmed sterilization cycles operate at low pressure and low temperature, suitable for processing medical devices without leaving toxic residues.
Each Cycle can sterilize non-lumened instruments and instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors.
The V-PRO 60 Sterilizer Non Lumen Cycle can sterilize:‡ Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes. ‡ The validation studies were conducted using a validation load consisting of one instrument tray for a total weight of 25 lbs (11.3 kg).
The V-PRO 60 Sterilizer Flexible Cycle can sterilize:@ STERIS Corporation Special Premarket Notification [510(k)] Modifications to V-PRO® s2 and V-PRO® 60 Low Temperature Sterilization Systems One surgical flexible endoscope (such as those used in ENT, Urology and Surgical Care) or bronchoscope with light cord (if not integral to endoscope), mat, and additional load.
• The flexible endoscope may be a single or dual lumen device with lumens that are ≥ 1 mm (~3/64”) internal diameter (ID) and ≤ 990 mm (38-63/64”) in.
• Additional load, up to 11 lb (5 kg) can include stainless steel lumens with the following dimensions o ≥ 0.76 mm (~1/32”) ID and ≤ 233 mm (~9 11/64”) in length o ≥ 1.0 mm (~3/64”) ID and ≤ 254 mm (~10”) in length o ≥ 1.8 mm (~5/64”) ID and ≤ 542 mm (~21 5/16”) in length @ The validation studies were conducted using a validation load consisting of two instrument trays. One tray contained one flexible endoscope, with silicone mat, instrument organizers and light cord (if not integral to scope), and the second tray contained additional load and twelve (12) stainless steel lumens for a total load weight of 11 lbs (5 kg). Hospital loads should not exceed the maximum number of lumens validated by this testing.
The V-PRO 60 Sterilizer Lumen Cycle can sterilize: ^ Medical devices (including single, dual and triple channeled rigid and semi-rigid endoscopes) with the following configurations:
• Single or dual channeled devices with stainless steel lumens that are ≥ 0.77 mm (~1/32”) ID and ≤ 410 mm (16-9/64”) in length ≥ 1.8 mm (~5/64”) ID x ≤ 542 mm (~21-5/16”) in length.
• Triple channeled devices with stainless steel lumens that are either: ≥ 1.2 mm (~3/64”) ID and ≤ 275 mm (~10-53/64”) in length ≥ 1.8 mm (~5/64”) ID and ≤ 310 mm (~12-13/64”) in length or ≥ 2.8 mm (~7/64”) ID and ≤ 317 mm (12-31/64”) in length ^ Validation testing for all lumen sizes was conducted using a maximum of twelve (12) stainless steel lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of one instrument tray and two pouches for a total weight of 11 lbs (5.0 kg).
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。