510(k)K190273

FDA DEVICE FACTS

T3 Platform software

Etiometry, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 8, 2019PRODUCT CODEMWI

Indications for use

The T3 Data Aggregation & Visualization software module is intended for the recording and display of multiple physiological parameters of the adult, pediatric, and neonatal patients from supported bedside devices. The software module is not intended for alarm notification or waveform display, nor is it intended to control any of the independent bedside devices to which it is connected. The software module is intended to be used by healthcare professionals for the following purposes:

• To remotely consult regarding a patient’s status, and

• To remotely review other standard or critical near real-time patient data in order to utilize this information to aid in clinical decisions and deliver patient care in a timely manner. The T3 Data Aggregation & Visualization software module can display numeric physiologic data captured by other medical devices:

• Airway flow, volume, and pressure

• Arterial blood pressure (invasive and non-invasive, systolic, diastolic, and mean)

• Bispectral index (BIS, signal quality index, suppression ratio)

• Cardiac Index

• Cardiac output

• Central venous pressure

• Cerebral perfusion pressure

• End-tidal CO2

• Heart rate

• Heart rate variability

• Intracranial pressure

• Left atrium pressure

• Oxygen saturation (intravascular, regional, SpO2)

• Premature ventricular counted beats

• Pulmonary artery pressure (systolic, diastolic, and mean)

• Pulse pressure variation

• Pulse Rate

• Respiratory rate

• Right atrium pressure

• Temperature (rectal, esophageal, tympanic, blood, core, nasopharyngeal, skin)

• Umbilical arterial pressure (systolic, diastolic, and mean) The T3 Data Aggregation & Visualization software module can display laboratory measurements including arterial and venous blood gases, complete blood count, and lactic acid. The T3 Data Aggregation & Visualization software module can display information captured by the T3 Risk Analytics Engine software module. The T3 Risk Analytics Engine software module calculates two indices: the IDO2 Index™ for inadequate delivery of oxygen and the IVCO2 Index™ for inadequate ventilation of carbon dioxide. IDO2 Index™ is indicated for use by health care professionals with post-surgical patients aged zero days to twelve years weighing 2 kg or more under intensive care. IDO2 Index™ is derived by mathematical manipulations of the physiologic data and laboratory measurements received by the T3 Data Aggregation & Visualization software module, version 3.3 or higher. When the IDO2 Index™ is elevated, it means that there is an increased risk of inadequate oxygen delivery and attention should be brought to the patient. The IDO2 Index™ presents partial quantitative information about the patient's cardiovascular condition, and no therapy or drugs can be administered based solely on the interpretation statements. IVCO2 Index™ is indicated for use by health care professionals with invasively ventilated patients aged 29 days to 12 years weighing 2 kg or more under intensive care. IVCO2 Index™ is derived by mathematical manipulations of the physiologic data and laboratory measurements received by the T3 Data Aggregation and Visualization software module, version 3.3 or higher. When the IVCO2 Index™ is increasing, it means that there is an increasing risk of inadequate carbon dioxide ventilation and attention should be brought to the patient. WARNINGS:

• Do not use the T3 Platform software as an active patient monitoring system.

• Do not use the T3 Platform software to replace any part of the hospital's device monitoring.

• Do not rely on the T3 Platform software as the sole source of patient status information.

• Do not use the IVCO2 Index as a substitute for arterial blood gases.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。