510(k)K190893

FDA DEVICE FACTS

Non-invasive Hemodynamic Blood Pressure Monitor

Vita-Course Technologies Co., Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEAugust 7, 2019PRODUCT CODEDXN

Indications for use

The Discovery 1 - Non-invasive Hemodynamic Blood Pressure Monitor device is a small, lightweight, handheld, device intended for measuring and display of Blood Pressure trending (systolic and diastolic) and spot-check of Peripheral pulse rate (PPR) and Peripheral pulse wave (PPW). Measurement is performing on capillary finger tip tissue (other than the thumb). The ring finger is the recommended site. The results of each measurement are stored in the The TensorTip - Non-invasive blood pressure trending device is a small, lightweight, handheld, device intended for measuring and display of Blood Pressure trending (systolic and diastolic) and spot-check of Peripheral pulse rate (PPR) and Peripheral pulse wave (PPW). Measurement is performing on capillary fingertip tissue (other than the thumb). The ring finger is the recommended site. The results of each measurement are stored in the system memory. The device is intended Same Vita-Course Technologies Co., Ltd. Features Subject Device Discovery 1 non-invasive Hemodynamic Blood Pressure Monitor Predicate Device K093981 TensorTipTM- Non-invasive Hemodynamic Blood Pressure Monitor Remark system memory. The device is intended for use in the home environment. It is intended to be used by any person aged above 18 years old. for use in the home environment. It is intended to be used by any person aged above 18 years old. Patient Population >18 years old >18 years old Same Principle of Operation Hemodynamics Hemodynamics Same Power source DC adaptor: 5Vd.c., Internal lithium polymer (Li-Pol) battery: 3.7Vd.c., 2200 mAh DC adaptor: 5Vd.c. Internal Li-Polymer battery: 3.7Vd.c., 740mAh Different 1) Blood pressure Systolic pressure range: 50 mmHg ~200 mmHg Diastolic pressure range: 40 mmHg ~160 mmHg Accuracy: ±5 mmHg Systolic pressure range: 90 mmHg ~ 240 mmHg Diastolic pressure range: 30 mmHg ~ 130 mmHg Accuracy: <10% Different 2) Pulse rate Measurement range: 40 bpm ~ 240 bpm Accuracy: ±2% or ±2 bpm, whichever is greater Measurement range: 30 bpm ~200 bpm Accuracy: Mean Square Error 0.5digits Different 3) Operating environment Temperature: 5 °C ~ 45 °C Humidity: 10% ~ 95% Temperature: 6 °C ~ 45 °C Humidity: 10 ~ 80% Different 4) IP degree IP22 IP00 Different 5) Standards IEC 60601-1 IEC 60601-1-2 IEC 60601-1-11 ISO 81060-2 IEC 60601-1 IEC 60601-1-2 ISO 81060-2 Different 6) Justifications for differences between Discovery 1 and the predicate device are shown as below: Different (1): The capacity of battery is different. However, the battery of subject device is in compliance with IEC 62133: 2012 - Secondary cells and batteries containing alkaline or other non -acid electrolytes - Safety requirements for portable sealed se condary cells, and for batteries made from them, for use in portable applications. Thus, this difference will not raise any safety or effectiveness issue. Different (2): The measurement range and the accuracy of blood pressure is different. The subject device is compliant with FDA recognized consensus standard ISO 81060-2: 2013. This difference will not raise any safety or effectiveness issue. Different (3): The measurement range and the accuracy of pulse rate is different. The subject device has been verified all the full claimed range. This difference will not raise any safety or effectiveness issue. Vita-Course Technologies Co., Ltd. Different (4): The operating environment is minor different. However, the difference will not raise any safety or effectiveness issue. Different (5): The degr ee of protection is different and the subject device is better than predicate device. The subject device is compliant with FDA recognized consensus standard IEC 60601 -1-11: 2015. This difference will not raise any safety or effectiveness issue. Different (6): The compliance standards are different. The subject device is compliant with FDA recognized consensus standard IEC 60601-1-11: 2015. This difference will not raise any safety or effectiveness issue.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 25, 2026