FDA DEVICE FACTS
ArtiSential Bipolar Fenestrated Forceps
Livsmed, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Electrosurgical coagulation, dissection, and grasping of tissue during the performance of laparoscopic and general surgical procedures. The ENSEAL® G2 Articulating Tissue Sealers are indicated for bipolar coagulation and mechanical transection of tissue during laparoscopic and open procedures. The devices are bipolar electrosurgical instruments for use with the Generator GEN11 (GEN11). They are intended for use during open or laparoscopic, general and gynecological surgery to cut and seal vessels, and to cut, grasp and dissect tissue during surgery. Indications for use include open and laparoscopic, general and gynecological surgical procedures (including urologic, thoracic, plastic and reconstructive, bowel resections, hysterectomies, cholecystectomies, gall bladder procedures, Nissen The Intuitive Surgical'" da Vinci Surgical System is intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments including rigid endoscopes, blunt and sharp endoscopic dissectors, scissors, scalpels, ultrasonic shears, forceps/pick-ups, needle holders, endoscopic retractors, stabilizers, electrocautery and accessories for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave ablation probes and accessories during urologic surgical procedures, general laparoscopic surgical procedures, gynecologic laparoscopic surgical procedures, general non-cardiovascular thoracoscopic K190909, ArtiSential Bipolar Fenestrated Forceps fundoplication, adhesiolysis, oophorectomies, etc.), or any procedure where vessel ligation (cutting and sealing), tissue grasping, and dissection is performed. The devices can be used on vessels up to (and including) 7mm and tissue and/or vascular bundles as large as will fit in the jaws of the instruments. surgical procedures, and thoracoscopically assisted cardiotomy procedures. The system can also be employed, with adjunctive mediastinotomy to perform coronary anastomosis during cardiac revascularization. It is intended for use by trained physicians in an operating room environment in accordance with the representative specific procedures set forth in the Professional Instructions for Use. Principles of operation This product is a single-use instrument used in electrosurgical units to hold soft tissues or coagulate and make an incision (tissue dissection) during general laparoscopic surgery, which uses the principle of applying high-frequency currents from the electrode to the human body to generate heat by bioimpedance when radio frequency (RF) energy from the electrosurgical unit applies an electric current to the electrode part, and using the generated heat to incise cellular tissues and cause coagulation. It is composed of a jaw, Φ8 diameter shaft, grip (including a control ring), and electrosurgical unit connection electrode connector. During a procedure with this product, the jaw opens if the control ring opens, and jaw closes if the control ring closes. In addition, the jaw is also bent up, down, left and right within a range of ±80° or more by moving the grip up, down, left and right, and the jaw can also The ENSEAL G2 Articulating Tissue Sealers have a 5 mm diameter shaft and are available in two shafts lengths: 35 and 45cm; and two jaw types: 3mm curved jaw and 5mm straight jaw. The jaws are normally in the opened position and can be partially or fully closed by squeezing the closing handle. The jaws have atraumnatic teeth for grasping and holding targeted tissue when clamped. The handles of the Subject ENSEAL G2 Articulating Tissue Sealers have an ergonomic interface for the user. Like the Predicate, the Subject devices include an integrated energy activation button. The devices use a combination of the application of bipolar electrosurgical energy in conjunction with the I- BLADE knife, to compress, coagulate, and transect tissue. This product is a reusable foot control electro-surgical electrode equipped with a product mounted on a cleared product like da Vinci S Surgical system or da Vinci Si Surgical System and used by connecting it to an electrosurgical machine with a cable. It consists of a housing, which is attached to the robotic arm of the da vinci system, and shaft which the bipolar energy is transferred and an electrode (tip) that coagulates, removes, dissects, or destroys tissues using the energy. The principles applied to the development of this product are as follows. When high-frequency energy from an electrosurgical machine is energized on the electrodes through cables, housings, and shafts, high-frequency currents from electrodes are applied to the human body to generate heat due to bio-resistance, and the heat generated is used to generate incision and coagulation of tissue. This product is a medical device that can be reused by K190909, ArtiSential Bipolar Fenestrated Forceps turn 360° when rotating the grip. cleaning and sterilizing after use. Energy Type Radiofrequency Radiofrequency Radiofrequency Electrode type (monopolar or bipolar) Bipolar Bipolar Bipolar Physical dimensions and design (size, length, connector type) Shaft diameter: 8mm Length: 411.4mm Connector type: Dual-pin connector type Shaft diameter: 5mm Length: 350mm, 450mm Connector type: Unknown Shaft diameter: 8mm Total length: 511mm Connector type: Dual-pin connector type Rated voltage 200 Vp Unknown 384 Vp Materials (electrode) Stainless steel Stainless steel Stainless steel Materials (insulation) Polyetherimide Unknown Polyetherimide / ETFE (Ethylenetetrafluoroethylene) Materials (Shaft) Glass fiber Unknown Glass fiber Rotation Pitch:±80° or more, Yaw:±80° or more and Open-Close Articulates approximately 50~65° to the left and the right of center and Open-Close Pitch:±70° Yaw:±90° Sterilization EO EO Moist Heat or Steam Sterilization
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。