FDA DEVICE FACTS
Terragene Bionova, Terragene Bionova, Terragene Integron, Terragene Cintape, Terragene Chemdye
Terragene S.A.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Terragene Bionova® SCBI (BT224) is a self-contained biological indicator inoculated with viable 10⁶ Geobacillus stearothermophilus bacterial spores and is intended for monitoring the efficacy of steam sterilization processes. On each Terragene Bionova® SCBI is a chemical process indicator that changes color from pink to brown when exposed to steam. Terragene Bionova® PCD (PCD224-C, PCD224-2) and Integron® PCD (PCD26-C, PCD26-2) provides a defined challenge resistance against the claimed cycles shown below and demonstrated resistance equivalence to the AAMI/ANSI 16 towel pack. The device provides routine monitoring and sterilizer qualification testing steam sterilization processes. Terragene Bionova® Reader Incubators (IC10/20FRLCD, Mini-Bio) incubate at 60° C and 37° C and read the Terragene Bionova® SCBI for fluorescent results at the times prescribed in the User Manuals. Terragene Bionova® SCBI (BT110) is a self-contained biological indicator inoculated with viable 10⁶ Bacillus atrophaeus bacterial spores and is intended for monitoring the efficacy of ethylene oxide sterilization processes. The integrator Terragene Integron® IT12 is designed to chemically react over time with the critical parameters of ethylene oxide sterilization cycle within a specified tolerance. The integrating indicator strip is intended to be placed in each pack, pouch, container, tray or other containment device to function as an independent monitor of critical parameters for the following sterilization cycles: 55°C for 240 minutes, 600 mg/l, RH 60 %. SV37°C/75 min., SV54°C/30 min, SV55ºC/28 min. Terragene Chemdye® CD16 is a chemical process indicator intended for monitoring the efficacy of ethylene oxide sterilization processes. The chemical indicator changes from purple/brown to green to indicate that the conditions of the cycle have been met. Terragene Bionova® SCBI (BT95, BT96) is a self-contained biological indicator inoculated with viable 10⁶ Geobacillus stearothermophilus bacterial spores and is intended for monitoring the efficacy of vaporized hydrogen peroxide sterilization processes. BT95 is Rapid Readout while BT96 is Super Rapid Readout. BT95 has Rapid readout at 2 hours at 60° C while BT96 has Super Rapid readout at 30 minutes at 60° C. Terragene Chemdye® (CD40, CD42) is a chemical process indicator intended for monitoring the efficacy of vaporized hydrogen peroxide sterilization processes. The chemical indicator changes from purple to green for CD40 and red to yellow for CD42 to indicate that the conditions of the cycle have been met. The integrator Terragene Integron® IT26-1YS is designed to chemically react over time with the critical parameters of steam sterilization cycle within a specified tolerance. The integrating indicator strip is intended to be placed in each pack, pouch, container, tray or other containment device to function as an independent monitor of critical parameters for the following sterilization cycles: Gravity Displacement: 121° C for 30 minutes, 132° C for 15 minutes, 132° C for 25 minutes, 135° C for 10 minutes; Dynamic Air Removal (Vacuum Assist): 132° C for 4 minutes, 135° C for 3 minutes. SV121° C/16.5 min., SV132° C/2.0 min, SV135° C/1.2 min. The integrator Terragene Integron® IT26-C is designed to chemically react over time with the critical parameters of steam sterilization cycle within a specified tolerance. The integrating indicator strip is intended to be placed in each pack, pouch, container, tray or other containment device to function as an independent monitor of critical parameters for the following sterilization cycles: Gravity Displacement: 121° C for 30 minutes, 132° C for 15 minutes, 132° C for 25 minutes, 135° C for 10 minutes; Dynamic Air Removal (Vacuum Assist): 132° C for 4 minutes, 135° C for 3 minutes. SV121° C/16.5 min., SV132° C/2.0 min, SV135° C/1.2 min.. Terragene Chemdye® CD29 is a chemical process indicator intended for monitoring the efficacy of steam sterilization processes. The chemical indicator changes from yellow to dark brown/black to indicate that the conditions of the cycle have been met. Terragene Cintape® CT22 is a chemical process indicator tape intended for monitoring the efficacy of steam sterilization processes. The indicating tape changes from yellow to dark brown/black when exposure to steam. Terragene Cintape® CT40 is a chemical process indicator tape intended for monitoring the efficacy of Vaporized Hydrogen Peroxide sterilization processes. The indicating tape changes from purple to green when exposure to vaporized hydrogen peroxide. Autoclave/Steam Cycles Gravity Displacement Models 121º C 132º C 135º C CD29, CT22, IT26-C, IT26-1YS 30 minutes 15 minutes, 25 minutes 10 minutes PCD26-C, PCD26-2 30 minutes NA NA BT224, PCD224-2, PCD224-C NA 15 minutes, 25 minutes 10 minutes BT224, PCD224-2, PCD224-C NA 10 minutes 10 minutes Dynamic Air Removal (Vacuum Assist) Models 121º C 132º C 135º C BT224, PCD224-2, PCD224-C, CD29, CT22, IT26-C, IT26-1YS NA 4 minutes 3 minutes PCD26-C, PCD26-2 NA 4 minutes NA Vaporized Hydrogen Peroxide Models Cycles BT95, BT96, CT40, CD42 STERRAD 100S 54 minutes STERRAD Standard and Express cycles V-Pro Max and Sterizone VP4 CD40 STERRAD 100S 54 minutes STERRAD Standard and Express cycles V-Pro Max Ethylene Oxide Models Cycles CD16, BT110, IT12 55º C for 240 minutes, 600 mg/L, RH 60 % Fluorescence Read Time and pH Color Change Models Fluorescence Read Time pH Color Change BT224, PCD224-2, PCD224-C 20 minutes 48 hours BT96 30 minutes 48 Hours BT95 2 Hours 48 Hours BT110 4 hours 48 Hours Minimum Stated Values (SV) for Chemical Integrators Autoclave/Steam Cycles Models 121 ºC 132 ºC 135 ºC IT26-C, IT26-1YS 16.5 minutes 2.0 minutes 1.2 minutes Ethylene Oxide (600mg/L) Models 37 ºC 54 ºC 55 ºC IT12 75 minutes 30 minutes 28 minutes
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。