FDA DEVICE FACTS
H500 Multi-Sensing Oximetry System
Nonin Medical, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Nonin Medical CO-Pilot™ Model H500 Multi-Sensing Oximetry System is intended for noninvasive measuring of functional oxygen saturation of arterial hemoglobin (%SpO2), pulse rate, carboxyhemoglobin saturation (%COHb), methemoglobin saturation (%MetHb), and cerebral or somatic hemoglobin oxygen saturation (%rSO2). This device is not meant for sole use in clinical decision making; it must be used in conjunction with additional methods of assessing clinical signs and symptoms.
• For %SpO2 and pulse rate, the H500 System is intended for spot-checking and/or measuring during clinician assessment of adult, pediatric, infant, and neonate patients who are well or poorly perfused, during both motion and non-motion conditions in professional healthcare facilities, mobile, and EMS settings.
• For %rSO2, the H500 System is intended for spot-checking and/or measuring during clinician assessment of adult, pediatric, infant, and neonate patients in professional healthcare facilities, mobile, and EMS settings.
• For %COHb and %MetHb, the H500 System is intended for spot-checking, multiple spot-checks to observe change, and/or measuring during clinician assessment of adult and pediatric patients in professional healthcare facilities, mobile, and EMS settings. The X-100 system is a modular system and is indicated for use in simultaneously measuring, displaying, monitoring, and recording up to six (6) channels of functional oxygen saturation of arterial hemoglobin (%SpO2) and pulse rate or cerebral or somatic hemoglobin oxygen saturation (%rSO2) of blood underneath the sensor. Patient populations include adult, pediatric, infant, and neonate through the use of SenSmart compatible sensors.
The SenSmart system is intended for use in hospitals, long-term care, medical facilities, sleep laboratories, sub-acute environments, and Emergency Medical Services (EMS), including patient transport. The X-100 SenSmart system may be used for spot-checking and continuous monitoring with patient alarms. The SenSmart pulse oxlmetry (SpO2) functionality Is suitable for use In both motion and non-motion conditions, Including patients who are well or poorly perfused. The X‐100C/Multi-Sensing Oximetry system is indicated for noninvasive measuring of functional oxygen saturation of arterial hemoglobin (%SpO2), carboxyhemoglobin saturation (%COHb), methemoglobin saturation (%MetHb), and pulse rate of adult and pediatric patients (>66 lbs / 30 kg) using the Model 8300AA/8330AA sensor. The measurements may be multiple spot‐checks to observe change and/or continuous monitoring. The systems are indicated for use by trained personnel in clinical and non‐clinical settings, including Emergency Medical Service (EMS), hospitals, medical facilities, and mobile environments. This device is not meant for sole use in clinical decision making; it must be used in conjunction with additional methods of assessing clinical signs and symptoms.
Use Environment Professional healthcare facilities, mobile, and EMS settings Hospitals, long-term care, medical facilities, sleep laboratories, sub-acute environments, and EMS settings Hospitals, medical facilities, mobile environments and EMS settings Compatible Sensor Accessories Same Compatible and intended to be used only with Nonin-branded oximeter sensors. Such sensors are manufactured to meet the accuracy specifications for Nonin oximeters and using other manufacturers’ sensors can result in improper oximeter performance.
Compatible Sensor Application Sites Same As specified in the respective sensor instructions for use Handheld or Tabletop? Handheld Tabletop Tabletop Wireless? Yes No No Includes Patient Alarms? No Yes Yes Principles of Operation Same Non-invasive oximetry using light-based measurement sharing the same measurement technology including optics specifications and signal processing algorithms. Range of SpO2 Same 0-100% Range of Pulse Rate (beats per minute) 18-321 bpm 18-300 bpm 18-321 bpm Range of rSO2 0-100% 0-100% N/A Range of COHb 0-99% N/A 0-99% Range of MetHb 0-99.9% N/A 0-99.9% Safety Specifications Same IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, ISO 80601-2-61 Specified Environmental Use Conditions Same All systems share the same specified operating temperature (5-40oC), storage/transport temperature and humidity (-30 to 70oC, up to 93%), operating humidity (15-93%) and operating altitude (0-4000m) Enclosure Degree of Ingress Protection Same IP33 Provided Sterile? Same No
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。