RARA CRAFT DATABASE for FDA Medical Devices
510(k)K192978

FDA DEVICE FACTS

EOGas 4 Ethylene Oxide Gas Sterilizer

Andersen Sterilizers, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATENovember 12, 2020PRODUCT CODEFLF

Indications for use

The EOGas 4 Ethylene Oxide Gas Sterilizer is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The critical process parameters for the two available cycles are summarized below: Table 1. EOGas 4 Ethylene Oxide Sterilizer cycle parameters EO Exposure Time Total Cycle Time EO Amount Temperature Relative Humidity 3 hours 3.5 hours 17.6 g ± 5% 50°C ± 3°C 35-70% 6 hours 7 hours The differences between the two options are the length of EO gas exposure and the length of mandatory ventilation after gas exposure; the gas exposure is chosen based on the devices to be sterilized. The appropriate purge probe and process challenge device (PCD) must be used: EOGas 4 SteriTest for a 3-hour gas exposure, EOGas 4 Endo-SteriTest for a 6-hour gas exposure. The EOGas 4 Ethylene Oxide Gas Sterilizer 3-hour gas exposure is used for surface sterilization of medical devices, including instruments with diffusion- restricted spaces (hinges or mated surfaces), as well as for the sterilization of endoscopes with working length shorter than 1100 mm as specified in the labeling. The EOGas 4 SteriTest PCD is used with the 3-hour gas exposure. The EOGas 4 Ethylene Oxide Gas Sterilizer 6 -hour gas exposure is used for sterilization of duodenoscopes and colonoscopes with working length longer than 1100 mm as specified in the labeling. The EOGas 4 Endo-SteriTest PCD is used with the 6-hour gas exposure. Table 2. Load and material types validated in the EOGas 4 Ethylene Oxide Gas Sterilizer Device Type Maximum Load Device Examples Required Aeration 3-Hour EO Exposure, EOGas 4 SteriTest PCD (Blue Purge Probe) Metal 24 lbs (11 kg) Surgical instruments, delicate sharps, including those with hinges and mated surfaces No additional aeration required; Follow pouch or wrap manufacturer’s instructions (Example: Tyvek pouches require ≥ 6 hours at 50°C) Plastic 7.0 lbs (3.2 kg) Reusable power cords, trocars, and similar devices 24 hours at 50°C; Follow manufacturer’s instructions Fabric 6.1 lbs (2.8 kg) Reusable cloth gowns, towels, and similar devices ≤ 1100 mm Working Lumen Length Endoscopes One (1) ≥ 2.0 mm ID biopsy channel ≤ 1100 mm working length Gastrovideoscopes, gastrointestinal videoscopes, and similar devices 8 hours at 50°C if in Sterisheet; Follow manufacturer’s instructions Four (4) ≥ 1.2 mm ID biopsy channel ≤ 700 mm working length Bronchoscopes, bronchovideoscopes, cystoscopes, ureteroscopes, choledocoscopes, and similar devices 6-Hour EO Exposure, EOGas 4 Endo-SteriTest PCD (Gold Purge Probe) >1100 mm Working Lumen Length Endoscopes Two (2) Duodenoscopes* ≥ 2.0 mm ID biopsy channel ≤ 1250 mm working length ≥ 1.2 mm ID, ≤ 3530 mm maximum length of any channel Olympus TJF-Q180V, Olympus TJF-Q160VF, Olympus TJF-Q190V, Olympus PJF-160, Fujifilm ED-530XT, Pentax ED34-i10T2 Pentax ED-3490TK 6 hours at 50°C for Olympus and Pentax endoscopes in Sterisheet; 8 hours at 50°C for Fujifilm endoscopes in Sterisheet; Follow manufacturer’s instructions Two (2) Colonoscopes* ≥ 3.7 mm ID biopsy channel ≤ 1700 mm working length ≥ 1.2 mm ID, ≤ 3530 mm maximum length of any channel Olympus CF-Q180AL, Fujifilm EC-600HL, Pentax EC-3490Li * One (1) duodenoscope may also be paired with one (1) colonoscope Reusable medical devices must be aerated following the instructions of the device manufacturer and the packaging material manufacturer. Devices are released for use after sterilization based on successful inactivation of a biological indicator (BI) in the Andersen EOGas 4 SteriTest (3-hour gas exposure) or EOGas 4 Endo-SteriTest (6-hour gas exposure) process challenge devices.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 24, 2026