FDA DEVICE FACTS
PENTAX Medical EG-J10U Endoscopic Ultrasound System - EG34-J10U Ultrasound Upper GI Video Scope (Convex Array Type), EG36-J10UR Ultrasound Upper GI Video Scope (Radial Array Type), EG38-J10UT Ultrasound Upper GI Video Scope (Convex Array Type)
Pentax of America, Inc.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The PENTAX Medical EG-J10U Endoscopic Ultrasound System is intended to provide optical visualization of, ultrasonic visualization of, and therapeutic access to, the Upper Gastrointestinal Tract including but not restricted to the organs, tissues, and subsystems: Esophagus, Stomach, Duodenum and underlying areas. The instrument is introduced per orally when indications consistent with the requirement for procedure are observed in adult and pediatric patient populations. Summary of Technology Characteristics: The PENTAX Medical EG-J10U Endoscopic Ultrasound System is functionally equivalent to its predicate device, the PENTAX Medical Endoscopic Ultrasound System cleared by FDA in 2018. The only difference between the two devices is that the predicate is used with the Legacy Ultrasound Video Gastroscopes, and the subject is used with the additional EG-J10U series of Ultrasound GI Video Scopes that includes EG34-J10U, EG36-J10UR and EG38-J10UT PENTAX Medical EG-J10U Endoscopic Ultrasound System The additional devices have been evaluated through performance testing and raise no issue of safety and effectiveness of the device as these differences have no effect on the performance, function or general intended use of the device. Non-Clinical Performance Data The PENTAX Medical EG-J10U Endoscopic Ultrasound System has been successfully tested for its functions, performance and safety as per FDA recognized consensus standards. The following performance data are provided in support of the substantial equivalence determination. Operational and Reprocessing Instructions for Use are provided for the scopes. Human Factors A human factors study to assess the ability of reprocessing staff to carry out the reprocessing instructions for use (rIFU) was conducted. The device was been found to be safe and effective for the intended patients, intended users, and in their use environments. Reprocessing Validation Simulated use testing, soil accumulation analysis, cleaning, and high-level disinfection validation studies of the EG34-J10U, EG36-J10UR and EG38-J10UT Upper GI Video Scopes and accessories were conducted and confirmed the effectiveness of reprocessing procedures. Sterilization and Shelf Life PENTAX Medical coordinated with STERIS Corporation to validate the use of System 1E liquid chemical sterilization for the sterilization of the EG-J10U series Ultrasound Upper GI Video Scopes. The devices are not provided sterile. PENTAX Medical conducted Gamma Ray Sterilization for packaging and for PENTAX Medical Ultrasound Balloons made of natural rubber latex. A shelf-life of 2 years after sterilization was verified. The labeling for the PENTAX Medical Ultrasound Balloons and their packaging prominently bears the 21 CFR 801.437 warning in bold: Caution: This product contains natural rubber latex which may cause allergic reactions. Also, the Operating Instructions for Use of the EG-J10U series of Ultrasound Upper GI Video Scopes prominently bears the warning in bold: Caution: The balloon contains natural rubber latex which may cause allergic reactions. PENTAX Medical EG-J10U Endoscopic Ultrasound System Software Software verification and validation tests were conducted and documentation was provided as recommended by FDA’s Guidance for Industry and FDA Staff, “Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices.” The software is classified as CLASS A under the Software Safety Classification per IEC 62304:2006, Medical device software- Software life cycle processes. The software level of concern is “Moderate” based on FDA’s Guidance for Industry and FDA Staff, “Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices.” Cybersecurity risks have been assessed and mitigated according to the FDA Guidances for Industry and Staff “Content of Premarket Submissions for Management of Cybersecurity in Medical Devices” issued October 2, 2014 and “Postmarket Management of Cybersecurity in Medical Devices.” issued December 28,2016. EMC and Electrical Safety The acceptable level of electromagnetic comp atibility (EMC) and electrical safety (ES) for the PENTAX Medical Endoscopic EG-J10U Ultrasound System were confirmed by the following standards: IEC 60601-1-2:2007; IEC 60601- 1:2005+CORR 1:2006+CORR 2:2007+A1:2012; IEC 60601-2-18:2009; and IEC 60601-2-37:2007. Optical Testing As a part of Design Verification and Validation, optical properties including signal to noise ratio, spatial resolution (MTF), distortion, light distribution, color (IEEE), spectral distribution and photobiological safety were measured for the EG34-J10U, EG36-J10UR and EG38-J10UT in conjunction with the EPK̺i5010 and EPK-i7010 video processors. All results show that there are no differences between the subject device, and the predicate device.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。