FDA DEVICE FACTS
EzRay Air Portable (Model: VEX-P300)
VATECH Co., Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
EzRay Air Portable (Model: VEX-P300) is an extraoral diagnostic dental X-ray source to produce X-ray images using intraoral image receptors. It is indicated for use by a dentist or a dental technician for both adult and pediatric patients. VEX-P300 is an extraoral diagnostic dental X-ray source to produce X-ray images using intraoral image receptors. It is indicated for use by a dentist or a dental technician for both adult and pediatric patients. Mech anical Size (L x W x H) 280 x 165 x 296 mm 280 x 165 x 296 mm Source to skin distance 200 mm 200 mm X-ray field Size 60 mm round 60 mm round User Interface Jog dial for operating mode selection. Additionally, several user-selectable preset times with patient size and tooth selection icons on a display module. Jog dial for operating mode selection. Additionally, several user-selectable preset times with patient size and tooth selection icons on a display module. Backscatter radiation protection 165 mm dia., Pb-filled acrylic plastic, Back Scattering shield 165 mm dia., Pb-filled acrylic plastic, Back Scattering shield Exposure Switch Exposure button on the handset Exposure button on the handset Tube head mounting Handheld Handheld Electr ical Energy source1 Rechargeable 21.6 V DC Li-ion polymer battery pack (Nominal Capacity: 2,500 mAh) Rechargeable 22.2 V DC Li-ion polymer battery pack (Nominal Capacity: 1,000 mAh or 900 mAh) Exposure time2 0.05 - 1.0 seconds in 0.01 increments 0.05 - 0.5 seconds in 0.01 increments mA 2.5 mA fixed 2.5 mA fixed kVp 60 or 65 kVp fixed 60 or 65 kVp fixed Waveform Constant Potential (DC) Constant Potential (DC) Applied Standard IEC 60601-1, IEC 60601-1-3, IEC 60601-2-65, IEC 60601-1-2, 21 CFR 1020.30, 1020.31 IEC 60601-1, IEC 60601-1-3, IEC 60601-2-65, IEC 60601-1-2, 21 CFR 1020.30, 1020.31 Note: The differences between the subject device and the predicate device, No. 1 and 2, are discussion in the Section 10 below. VATECH Co., Ltd. Premarket Notification 510(k)
Page 4 / 5
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。