FDA DEVICE FACTS
AVIEW
Coreline Soft Co., Ltd
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
AVIEW provides CT values for pulmonary tissue from CT thoracic and cardiac datasets. This software could be used to support the physician quantitatively in the diagnosis, follow up evaluation and documentation of CT lung tissue images by providing image segmentation of sub-structures in lung, lobe, airways and cardiac, registration of inspiration and expiration which could analyze quantitative information such as air trapping volume, air trapped index, and inspiration/ expiration ratio. And also, volumetric and structure analysis, density evaluation and reporting tools. AVIEW is also used to store, transfer, inquire and display CT data set on premise and as cloud environment as well to allow users to connect by various environment such as mobile devices and chrome browser. Characterizing nodules in the lung in a single study, or over the time course of several thoracic studies. Characterizations include nodule type, location of the nodule and measurements such as size (major axis, minor axis), estimated effective diameter from the volume of the nodule, volume of the nodule, Mean HU(the average value of the CT pixel inside the nodule in HU), Minimum HU, Max HU, mass(mass calculated from the CT pixel value), and volumetric measures(Solid major; length of the longest diameter measured in 3D for solid portion of the nodule, Solid 2nd Major: The length of the longest diameter of the solid part, measured in sections perpendicular to the Major axis of the solid portion of the nodule), VDT (Volume doubling time), and Lung-RADS (classification proposed to aid with findings). The system automatically performs the measurement, allowing lung nodules and measurements to be displayed and, integrate with FDA certified Mevis CAD (Computer aided detection) (K043617). It also provides CAC analysis by segmentation of four main artery (right coronary artery, left main coronary, left anterior descending and left circumflex artery then extracts calcium on coronary artery to provide Agatston score, volume score and mass score by whole and each segmented artery type. Based on the score, provides CAC risk based on age and gender.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。