RARA CRAFT DATABASE for FDA Medical Devices
510(k)K200875

FDA DEVICE FACTS

ArtiSential Laparoscopic Instruments - Electrodes

Livsmed, Inc.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJune 17, 2020PRODUCT CODEGEI

Indications for use

Electrosurgical coagulation, dissection, and grasping of tissue during the performance of laparoscopic and general surgical procedures. Electrosurgical coagulation, dissection, and grasping of tissue during the performance of laparoscopic and general surgical procedures. Principles of operation This product is a single-use instrument used in electrosurgical units to hold soft tissues or coagulate and make an incision (tissue dissection) during general laparoscopic surgery, which uses the principle of applying high-frequency currents from the electrode to the human body to generate heat by bioimpedance when radio frequency (RF) energy from the electrosurgical unit applies an electric current to the electrode part, and using the generated This product is a single-use instrument used in electrosurgical units to hold soft tissues or coagulate and make an incision (tissue dissection) during general laparoscopic surgery, which uses the principle of applying high-frequency currents from the electrode to the human body to generate heat by bioimpedance when radio frequency (RF) energy from the electrosurgical unit applies an electric current to the electrode part, and using the generated ArtiSential Laparoscopic Instruments-Electrodes Page 3 / 4 heat to incise cellular tissues and cause coagulation. It is composed of a jaw, Φ8 diameter shaft, grip (including a control ring), and electrosurgical unit connection electrode connector. During a procedure with this product, the jaw opens if the control ring opens, and jaw closes if the control ring closes. In addition, the jaw is also bent up, down, left and right within a range of ±80° or more by moving the grip up, down, left and right, and the jaw can also turn 360° when rotating the grip. heat to incise cellular tissues and cause coagulation. It is composed of a jaw, Φ8 diameter shaft, grip (including a control ring), and electrosurgical unit connection electrode connector. During a procedure with this product, the jaw opens if the control ring opens, and jaw closes if the control ring closes. In addition, the jaw is also bent up, down, left and right within a range of ±80° or more by moving the grip up, down, left and right, and the jaw can also turn 360° when rotating the grip. Energy Type Radiofrequency Radiofrequency Electrode type (monopolar or bipolar) Bipolar Bipolar Physical dimensions and design (size, length)

- Shaft diameter: 8mm

- Shaft Length: 250mm, 380mm, 450mm

- Shaft diameter: 8mm

- Shaft Length: 380mm Rated voltage 200Vp 200Vp Materials (electrode) Stainless steel Stainless steel Materials (insulation) Polyetherimide Polyetherimide Materials (Shaft) Glass fiber Glass fiber Articulating feature Pitch:±80° or more, Yaw:±80° or more and Open-Close Pitch:±80° or more, Yaw:±80° or more and Open-Close Tip rotation 360° 360° Sterilization EO EO

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 24, 2026