RARA CRAFT DATABASE for FDA Medical Devices
510(k)K201643

FDA DEVICE FACTS

ChoiceSpine Tiger Shark Cervical Spacer System

Choice Spine, LLC

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEDecember 22, 2020PRODUCT CODEODP

Indications for use

x ODP The purpose of this submission is to gain clearance for adding an additional titanium implant footprint in 18x15mm size and inst ruments to the ChoiceSpine Tiger Shark™ Cervical Spacer System. This device has been previously submitted as ChoiceSpine Stealth™ Cervical Spacer System, (K183397) and has undergone additional technical upgrades per ChoiceSpine design contro l including porous titanium regions and a slight change in profile within the scope of K183397. It has since been trade marked as Tiger Shark™ Cervical Spacer System. The ChoiceSpine Tiger Shark™ Cervical Spacer System consists of intervertebral body fusion devices comprised of titanium alloy (Ti -6AI-4V ELI pe r ASTM F3001, Class C). The spacers have a basic oval shape that coincides with the shape of vertebral bodies and a hollow center for placement of bone graft. They are available in an assortment of heights and in multiple angles of lo rdosis to accommodate different anatomic requirements. The devices are manufactured using the Electron Beam Melting (EBM) additive manufacturing method. The Tiger Shark™ Cervical Spacer System is intended for anterior cervical spine intervertebral body fusion at one level from the C2-C3 disc space to the C7-T1 disc for the treatment of degenerative disc disease (DDD) in skeletally mature patients who have had six (6) week s of non- operative treatment. DDD is defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The Tiger Shark™ Cervical Spacer System is to be used with supplemental fixation and with autogenous bone graft and/or allogeni c bone graft comprised of cancellous and/or cortico-cancellous bone graft to facilitate fusion. Materials The implants are made from either titanium alloy (Ti-6Al-4V ELI per ASTM F3001, Class C). Implants will be provided sterile. Instruments will be provided non- sterile but will be steam sterilized before use. The instrumentation is made from 455/465 SS per ASTM A564, 17-4 SS per ASTM F899 and 6061 T6 Aluminum per ASTM B209/B221.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 24, 2026