RARA CRAFT DATABASE for FDA Medical Devices
510(k)K201690

FDA DEVICE FACTS

Mirage Hydrophilic Guidewire; X-pedion Hydrophilic Guidewire

Micro Therapeutics, Inc. d/b/a ev3 Neurovascular

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEJuly 21, 2020PRODUCT CODEDQX

Indications for use

Statement The Hydrophilic Guidewire is indicated for general intravascular use to aid in the selective placement of catheters in the peripheral, visceral and cerebral vasculature during diagnostic and/or therapeutic procedures. Same Dimensions Nominal Wire Diameter Mirage™: 0.008” Same X-pedion™: 0.010” Same Device Length 200 cm ± 2.5 cm. Same Tip Length 10 cm Same Tip Type and Shape Shapeable to 90° Same Coating Length 170 cm Same Material Coil Platinum Same Wire Stainless-Steel Same Coating Hydrophilic Same Packaging Pouch Polyester/Tyvek Same Carton 0.020” Solid Bleached Sulfate Same Accessories Pin Vise Yes Same Introducer Needle Yes Same Sterilization Method Ethylene Oxide (EO) Same Stability Shelf Life 12 Months 36 Months Performance Data – Bench: The following non-clinical bench testing was performed to evaluate the performance of the Mirage™ and X-pedion™ Hydrophilic Guidewires. The successful results of the testing demonstrated that the changes do n ot raise questions of safety and effectiveness, supporting the substantial equivalence to the predicate device. Test Test Method Summary Results Performance Visual Inspection and Dimensional Verification The Mirage™ and X-pedion™ Hydrophilic Guidewires were evaluated per QP50324. The Mirage™ and X-pedion™ Hydrophilic Guidewires met the acceptance criteria for visual inspection and dimensional verification. Friction Force The Mirage™ and X-pedion™ Hydrophilic Guidewires were evaluated per TM0047. The Mirage™ and X-pedion™ Hydrophilic Guidewires met the acceptance criteria for friction force. Mirage™ and X-pedion™ Hydrophilic Guidewires June 18 ,2020 Test Test Method Summary Results Flexing The Mirage™ and X-pedion™ Hydrophilic Guidewires were evaluated per ISO 11070. The Mirage™ and X-pedion™ Hydrophilic Guidewires met the acceptance criteria for flexing. Particulate The Mirage™ and X-pedion™ Hydrophilic Guidewires were evaluated per USP <788>. The Mirage™ and X-pedion™ Hydrophilic Guidewires met the acceptance criteria for particulate. Tensile Strength The Mirage™ and X-pedion™ Hydrophilic Guidewires were evaluated per ISO 11070. The Mirage™ and X-pedion™ Hydrophilic Guidewires met the acceptance criteria for tensile strength. Corrosion Resistance The Mirage™ and X-pedion™ Hydrophilic Guidewires were evaluated per ISO 11070. The Mirage™ and X-pedion™ Hydrophilic Guidewires met the acceptance criteria for corrosion resistance. Performance Data – Animal: There is no change to the Indication for Use (IFU) Statement for the Mirage™ and X-pedion™ Hydrophilic Guidewires in comparison to the legally marketed predicate device. The differences in technological characteristics do not raise questions of safety and effectiveness as demonstrated through non-clinical bench testing using well-established acceptable scientific methods. Performance Data – Clinical: There is no change to the Indication for Use (IFU) Statement for the Mirage™ and X-pedion™ Hydrophilic Guidewires in comparison to the legally marketed predicate device. The differences in technological characteristics do not raise questions of safety and effectiveness as demonstrated through non-clinical bench testing using well-established acceptable scientific methods.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン