RARA CRAFT DATABASE for FDA Medical Devices
510(k)K202234

FDA DEVICE FACTS

NervAlign Nerve Cuff

Renerve, Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEFebruary 10, 2022PRODUCT CODEJXI

Indications for use

The NervAlign® Nerve Cuff is indicated for the repair of peripheral nerve injuries in which there is no gap or where a gap closure is achieved by flexion of the extremity.

Comparison of Technological Characteristics with the Predicate Device The proposed device is substantially equivalent to the design and materials in the predicate device. The table below summarizes the comparison between the predicate device and the NervAlign® Nerve Cuff.

NervAlign® Nerve Cuff Comparison to AxoGuard Nerve Protector Feature NervAlign® Nerve Cuff [Proposed Device] AxoGuard Nerve Protector [Predicate Device] 510(k) K202234 K132660 Device Class Class II Class II Classification Name and Number Nerve Cuff; 21 CFR 882.5275 Nerve Cuff; 21 CFR 882.5275 Product Code JXI JXI Indications for Use The NervAlign® Nerve Cuff is indicated for the repair of peripheral nerve injuries in which there is no gap or where a gap closure is achieved by flexion of the extremity. The Nerve Cuff is indicated for the repair of peripheral nerve injuries in which there is no gap or where a gap closure is achieved by flexion of the extremity. The device is provided sterile and intended for one-time use. Principles of Operation Collagen matrix intended to wrap and repair damaged peripheral nerves Collagen matrix intended to wrap and repair damaged peripheral nerves Material Collagen Matrix - Porcine Pericardium Collagen Matrix – Porcine Small Intestinal Submucosa (SIS) Sterile/Single Use Sterile; single use Sterile; single use Sterilization Method Gamma Irradiation Ethylene Oxide (EtO)

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 23, 2026