Aline Ablation Intelligence

Mirada Medical, Ltd.

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATESeptember 11, 2020PRODUCT CODELLZ

Indications for use

Aline Ablation Intelligence is a Computed Tomography (CT) and Magnetic Resonance (MR) image processing software package available for use with ablation procedures. Aline Ablation Intelligence is controlled by the user via a user interface on a workstation. Aline Ablation Intelligence imports images from CT and MR scanners and facility PACS systems for display and processing during ablation procedures. Aline Ablation Intelligence is used to assist physicians in planning ablation procedures, including identifying ablation targets and virtual ablation needle placement. Aline Ablation Intelligence is used to assist physicians in confirming ablation zones. The software is not intended for diagnosis. The software is not intended to predict ablation volumes or predict ablation success. Technical characteristic comparison Characteristic Aline Ablation Intelligence NeuWave – Ablation Confirmation Equivalence 510(k) number K202297 K150313 n/a mm9777-4 QALS-RA

Copyright © Mirada Medical Ltd, 2020

Classification Class II. 892.2050 LLZ Class II. 892.2050 LLZ n/a Target Population The intended patient population of the Aline Ablation Intelligence software is the patient demographic chosen by interventional radiologists to undergo ablation treatment (including patient with soft tissue lesions). Patient with soft tissue lesions. Equivalent Where Used The application’s use environment is the Operating Room and the hospital healthcare environment such as interventional radiology control room. Ablation Confirmation™ (AC), is a Computed Tomography (CT) image processing software package available as an optional feature for use with the Certus® 140 2.45 GHz Ablation System. AC is controlled by the user via an independent user interface on a second monitor separate from the Certus 140 user interface. All AC processing and viewing is accomplished at the Certus® 140 Ablation System without the physician having to leave the procedure area to utilize separate image processing tools. Substantially Equivalent Energy Used and/or Delivered None – software only application. The software application does not deliver or depend on energy delivered to or from patients None – software only application. The software application does not deliver or depend on energy delivered to or from patients, this image processing software package is an optional for use with the Certus® 140 2.45 GHz Ablation System Equivalent Intended Users Physicians Physicians Equivalent Design: Supported modalities CT, MRI. CT, MRI. Equivalent Design: Data Visualization Window and level, pan, zoom, cross-hairs, slice navigation Window and level, pan, zoom, cross-hairs, slice navigation Equivalent mm9777-4 QALS-RA

Copyright © Mirada Medical Ltd, 2020

Design: Image Segmentation Tools for segmenting 3D VOIs, including target tissues and ablation zones. Tools for segmenting 3D VOIs, including target lesions and ablation zones. Equivalent Design: Image registration Registration of multiple images into a single view. Registration of multiple images into a single view. Equivalent Design: Ablation zone confirmation Aline Ablation Intelligence can perform a registration of the planning scan, containing the identified target tissue, with the confirmation scan showing the ablation zone. The delineated target tissue on the planning scan is then projected onto the confirmation scan and overlaid onto the delineated ablation zone segmentation. This to help the user in analyzing if the ablation zone covers the target tissue with the desired amount of margin. AC can then perform a registration of the initial CT scan, containing the identified target, with the final CECT scan containing the segmented ablation zone. The resulting image set includes the ablation zone overlaid onto the initial target lesion segmentation to help physicians determine the technical success (ablation zone covers target lesion with desired amount of margin) of the ablation procedure. Substantially Equivalent Design: Save key images to PACS Key images can be acquired which may be saved back to PACS or any DICOM nodes. All snapshot taken during procedure are stored to PACS. Substantially Equivalent Human Factors Intended to be used safely and effectively by trained physicians and a human factors engineering process has been undertaken, adhering to IEC 62366-1:2015. Unknown Substantially Equivalent

Materials Not applicable - software device only Not applicable - software device only n/a Biocompatibility Not applicable - software device only Not applicable - software device only n/a Sterility Not applicable - software device only Not applicable - software device only n/a Electrical safety Not applicable - software device only Not applicable - software device only n/a Mechanical Safety Not applicable - software device only Not applicable - software device only n/a mm9777-4 QALS-RA

Copyright © Mirada Medical Ltd, 2020

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。