510(k)K202536

FDA DEVICE FACTS

Non-sterile, Powder Free Nitrile Examination Aloe Vera Gloves, Low Dermatitis Potential, Tested for use with Chemotherapy Drugs, And Non-Sterile, Powder Free Nitrile Examination Gloves, Tested for use with Chemotherapy Drugs and Fentanyl Citrate

Yty Industry (Manjung) Sdn Bhd

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATEAugust 11, 2021PRODUCT CODELZA

Indications for use

A patient examination glove is a disposable device intended for medical purpose that is worn on the examiner’s hand or finger to prevent contamination between patient and examiner. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs: Aloe Vera Tested Chemotherapy Drug And Concentration Average Breakthrough Detection Time (minutes) Carboplatin, 10 mg/m] > 240 minutes Carmustine, 3.3 mg/ml 11.0 minutes Cisplatin (BCNU), 1.0 mg/ml > 240 minutes Cyclophosphamide (Cytoxan), 20.0 mg/ml > 240 minutes Dacarbazine (DTIC), 10.0 mg/ml > 240 minutes Doxorubicin Hydrochloride, 2.0 mg/ml > 240 minutes Etoposide (Toposar), 20.0 mg/ml > 240 minutes Fluorouracil, 50.0 mg/ml > 240 minutes Ifosfamide, 50.0 mg/ml > 240 minutes Methotrexate, 25 mg/ml > 240 minutes Mitomycin C, 0.5 mg/ml > 240 minutes Mitoxantrone, 2 mg/ml > 240 minutes Paclitaxel (Taxol), 6.0 mg/ml > 240 minutes ThioTEPA, 10.0 mg/ml 59.0 minutes Vincristine Sulfate, 1.0 mg/ml > 240 minutes The following chemotherapy drugs and concentration have extremely low permeation time. Carmustine (3.3 mg/ml): 11.0 minutes ThioTEPA (10.0 mg/ml): 59.0 minutes WARNING: NOT TO BE USED WITH CARMUSTINE OR THIOTEPA A patient examination glove is a disposable device intended for medical purpose that is worn on the examiner’s hand or finger to prevent contamination between patient and examiner. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs: Fentanyl Tested Chemotherapy Drug And Concentration Average Breakthrough Detection Time (minutes) Carboplatin, 10 mg/m] > 240 minutes Carmustine, 3.3 mg/ml 15.0 minutes Cisplatin (BCNU), 1.0 mg/ml > 240 minutes Cyclophosphamide (Cytoxan), 20.0 mg/ml > 240 minutes Dacarbazine (DTIC), 10.0 mg/ml > 240 minutes Doxorubicin Hydrochloride, 2.0 mg/ml > 240 minutes Etoposide (Toposar), 20.0 mg/ml > 240 minutes Fluorouracil, 50.0 mg/ml > 240 minutes Ifosfamide, 50.0 mg/ml > 240 minutes Methotrexate, 25 mg/ml > 240 minutes Mitomycin C, 0.5 mg/ml > 240 minutes Mitoxantrone, 2 mg/ml > 240 minutes Paclitaxel (Taxol), 6.0 mg/ml > 240 minutes ThioTEPA, 10.0 mg/ml 30.1 minutes Vincristine Sulfate, 1.0 mg/ml > 240 minutes Fentanyl Citrate, 100mcg/2ml > 240 minutes The following chemotherapy drugs and concentration have extremely low permeation time. Carmustine (3.3 mg/ml): 15.0 minutes ThioTEPA (10.0 mg/ml): 30.1 minutes WARNING: NOT TO BE USED WITH CARMUSTINE OR THIOTEPA

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 23, 2026