Amsco Evolution Medium Steam Sterilizer (Models HC-900 and HC-1200),Evolution Automated Loading and Unloading System (ALUS); Amsco EvolutionMedium Steam Sterilizer (Models HC-600 and HC-1500),Evolution Automated Loading and Unloading System (ALUS); Amsco EvolutionMedium Steam Sterilizer (Models HC-800 and HC-1000),Evolution Automated Loading and Unloading System (ALUS)
STERIS Corporation
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
• Prevacuum – is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.
• Steam Flush Pressure-Pulse (SFPP) – is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. The Amsco Evolution Medium Prevacuum Steam Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 6-1): Ta ble 6-1. Evolution Medium Prevacuum Steam Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-3 for recommended quantities. Prevac 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 6-3 for recommended quantities. Liquid* 250°F (121°C) 45 minutes N/A Refer to Table 6-4 for recommended quantities. Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 250°F (121°C) 30 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 270°F (132°C) 25 minutes 15 minutes Fabric Packs. Refer to Table 6-3 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A Table 6-2. Evolution Medium Steam Flush Pressure-Pulse (SFPP) Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load SFPP 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-3 for recommended quantities. SFPP 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-3 for recommended quantities. Gravity 250°F (121°C) minutes 15 minutes Fabric Packs. Refer to Table 6-3 for recommended quantities. SFPP 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Gravity 270°F (132°C) minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-3 for recommended quantities. Liquid* 250°F (121°C) minutes N/A Refer to Table 6-4 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A Ta ble 6-3. Evolution Medium Steam Sterilizer recommended loads per sterilizer size Sterilizer Size Wrapped Instrument Trays Fabric Packs 26” x 37 ½” x 42” 12 18 26” x 37 ½” x 54” 16 30 The following table is a guideline for liquid cycle processing: Ta ble 6-4. Evolution Medium Steam Sterilizer Liquid Cycle* Guideline Number of Containers Volume of Liquid In One Container Minimum Recommended Sterilize Time at 250ºF (121ºC) 3 1000 ml 45 minutes T he Amsco Evolution Medium Steam Sterilizer is offered in the following chamber sizes:
• 26” x 37½” x 42” (Model HC – 900)
• 26” x 37½” x 54” (Model HC – 1200) The Evolution Automated Loading and Unloading System (ALUS) is used for automated loading and unloading the Evolution Medium Steam Sterilizers.
• Prevacuum – is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.
• Steam Flush Pressure-Pulse (SFPP) – is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. The Amsco Evolution Medium Prevacuum Steam Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 6-5): Ta ble 6-5. Evolution Medium Prevacuum Steam Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-7 for recommended quantities. Prevac 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 6-7 for recommended quantities. Liquid* 250°F (121°C) 45 minutes N/A Refer to Table 6-8 for recommended quantities. Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-7 for recommended quantities. Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-7 for recommended quantities. Gravity 250°F (121°C) 30 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-7 for recommended quantities. Gravity 270°F (132°C) 25 minutes 15 minutes Fabric Packs. Refer to Table 6-7 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A Table 6-6. Evolution Medium Steam Flush Pressure-Pulse (SFPP) Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load SFPP 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-7 for recommended quantities. SFPP 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-7 for recommended quantities. Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-7 for recommended quantities. Gravity 250°F (121°C) minutes 15 minutes Fabric Packs. Refer to Table 6-7 for recommended quantities. SFPP 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-7 for recommended quantities. Gravity 270°F (132°C) minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-7 for recommended quantities. Liquid* 250°F (121°C) minutes N/A Refer to Table 6-8 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A Table 6-7. Evolution Medium Steam Sterilizer recommended loads per sterilizer size Sterilizer Size Model Number Wrapped Instrument Trays Fabric Packs 26” x 26” x 39” HC-600 9 12 26” x 37 ½” x 66” HC-1500 20 36 The following table is a guideline for liquid cycle processing: Ta ble 6-8. Evolution Medium Steam Sterilizer Liquid Cycle* Guideline Number of Containers Volume of Liquid In One Container Minimum Recommended Sterilize Time at 250ºF (121ºC) 3 1000 ml 45 minutes T he Evolution Automated Loading and Unloading System (ALUS) is used for automated loading and unloading the Evolution Medium Steam Sterilizers.
• Prevacuum – is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.
• Steam Flush Pressure-Pulse (SFPP) – is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. The Amsco Evolution Medium Prevacuum Steam Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 6-1): Table 6-9. Evolution Medium Prevacuum Steam Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-11 for recommended quantities. Prevac 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 6-11 for recommended quantities. Liquid* 250°F (121°C) 45 minutes N/A Refer to Table 6-12 for recommended quantities. Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-11 for recommended quantities. Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-11 for recommended quantities. Gravity 250°F (121°C) 30 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-11 for recommended quantities. Gravity 270°F (132°C) 25 minutes 15 minutes Fabric Packs. Refer to Table 6-11 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A Table 6-10. Evolution Medium Steam Flush Pressure-Pulse (SFPP) Sterilizer factory-programmed sterilization cycles and cycle values Cycles Sterilize Temperature Sterilize Time Dry Time Recommended Load SFPP 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-11 for recommended quantities. SFPP 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-11 for recommended quantities. Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 6-11 for recommended quantities. Gravity 250°F (121°C) minutes 15 minutes Fabric Packs. Refer to Table 6-11 for recommended quantities. SFPP 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-11 for recommended quantities. Gravity 270°F (132°C) minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 6-11 for recommended quantities. Liquid* 250°F (121°C) minutes N/A Refer to Table 6-12 for recommended quantities. DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack Leak Test N/A N/A N/A N/A Table 6-11. Evolution Medium Steam Sterilizer recommended loads per sterilizer size Sterilizer Size Wrapped Instrument Trays Fabric Packs 26” x 26” x 49” 12 16 26” x 26” x 61” 15 20 The following table is a guideline for liquid cycle processing: Table 6-12. Evolution Medium Steam Sterilizer Liquid Cycle* Guideline Number of Containers Volume of Liquid In One Container Minimum Recommended Sterilize Time at 250ºF (121ºC) 3 1000 ml 45 minutes The Amsco Evolution Medium Steam Sterilizer is offered in the following chamber sizes:
• 26” x 26” x 49” (Model HC – 800)
• 26” x 26” x 61” (Model HC – 1000) The Evolution Automated Loading and Unloading System (ALUS) is used for automated loading and unloading the Evolution Medium Steam Sterilizers.