Veuron-Brain-mN1
Heuron Co., Ltd.
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
Veuron-Brain-mN1 is intended for use in the post-acquisition image enhancement of 3T MR images of the brain acquired through a 3D gradient-echo sequence. When used in combination with other clinical information, the Veuron-Brain-mN1 application may aid the qualified radiologist with diagnosis by providing enhanced visualization of tissue structures with magnetic susceptibility contrasts in brain 3T MR images. Comparison of indications for use statement The following table compares indications for use statements between the Veuron-Brain-mN1 and the predicate device (i.e. SPIN-SWI application software). Similar to the predicate device, the Veuron-Brain-mN1 is used for managing patient and case base data, collection, analysis and display of the medical images. The device assists the clinician with the visual evaluation, manipulation, and assessment of pathologies derived from brain scans. Veuron-Brain-mN1 SPIN-SWI Subject device (K203279) Pr edicate device (K173224) Veuron-Brain-mN1 is intended for use in the post-acquisition image enhancement of 3T MR images of the brain acquired through a 3D gradient-echo sequence. When used in combination with other clinical information, the Veuron-Brain-mN1 application may aid the qualified radiologist with diagnosis by providing enhanced visualization of tissue structures with magnetic susceptibility contrasts in brain 3T MR images. The SpinTech, Inc. SPIN- SWI application is intended for use in the post-acquisition image enhancement of MRI acquired 3D gradient-echo images of the brain. When used in combination with other clinical information, the SPIN-SWI application may aid the qualified radiologist with diagnosis by providing enhanced visualization of structures containing venous blood such as cerebral venous vasculature. Summary of the technological characteristics compared to the predicate device and new device. The software is similar in uses and application to the predicate device. As stated in the comparison table provided below, both the device and predicates are used to assist the clinician with the visual evaluation, manipulation, and assessment of pathologies derived from brain scans. Comparison item Veuorn-Brian-mN1 Subject device (K203279) SpinTech, Inc. SPIN-SWI application software Predicate device (K173224) Target user Qualified radiologist Qualified radiologist and technologist Anatomical site Brain Brain Where used Hospital Hospital Heuron Co., Ltd. 10th Floor, 7, Mirae-ro, Namdong-gu Incheon, 21558 Republic of Korea Tel. +82-32-429-8508 / Fax. +82-32-429-8507 Design features ·Import DICOM data ·Perform automatic post-processing ·Provide the user confirmation ·Export the resulting data only through USB ·Import DICOM data ·Perform automatic post-processing ·Provide the user confirmation ·Export the resulting data through data network Non-clinical performance · Bench testing performed to the test functionality of the system. ·Bench testing performed to the test functionality of the system. Standards · ISO 14971 · ISO 62304 · IEC 62366 · ISO 14971 · ISO 62304 SW verification and validation Tested in accordance with verification and validation process and planning. The testing results support that all the system requirements have met their acceptance criteria and are adequate for its intended use. Tested in accordance with verification processes and planning, The testing results support that all the system requirements have met their acceptance criteria and are adequate for its intended use. Compatible input data format and modality · DICOM · MRI (Siemens Healthcare, Philips, 3.0T) · DICOM · MRI Input patient data Manual th rough keyboard / mouse Unknown Output patient data format DICOM · Unknown Study list functionality Se arch, Importing and Exporting Search, Importing and Exporting Non-clinical study performance Bench testing is done to show that the system is suitable for its intended use. In order to evaluate the safety of the product, unit tests and integration tests were performed, and all results met the acceptance criteria. The device performance was evaluated using phantom testing representing the range of susceptibility values in the brain tissue. Additionally, the device performance was also evaluated on clinical images using CNR/SNR metrics. The scanner models used for the testing were Siemens Healthcare's and Philips's and field strength was 3T. The predefined acceptance criteria were met to demonstrate substantial equivalence to the predicate.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。