RARA CRAFT DATABASE for FDA Medical Devices
510(k)K210513

FDA DEVICE FACTS

UNIWEB Surgical Mask, Model: ASTM Level 1, UNIWEB Surgical Mask, Model: ASTM Level 2

Universal Incorporation

FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。

DECISION DATESeptember 29, 2021PRODUCT CODEFXX

Indications for use

The Surgical Mask is intended to be worn to protect both the patient and healthcare personnel from the transfer of microorganisms, body fluids and particulate material. This device is intended for adult use Only. The UNIWEB Surgical Masks are single use, disposable device, provided non-sterile. WestTec Procedure and Surgical facemasks are intended to be worn by healthcare workers to protect the user and patient against transfer of microorganisms, blood and body fluids, and airborne particulates. The WestTec Procedure and Surgical facemasks are single use, disposable devices provided non-sterile. Same Dimensions 175 mm x 95 mm 175 mm x 90 mm Similar Layers Three Three Same Mask Style Flat-pleated Flat-pleated Same Design Feature Ear loops Ear loops Same Sterility Non-Sterile Non-Sterile Same Use Single Use Single Use Same Material: Surface Layer: Polypropylene Spunbond Middle Layer: Polypropylene Meltblown Bottom Layer: Polypropylene Spunbond Nose Wire: galvanized iron wire covered with polyethylene Ear Loops: Nylon and Spandex Outer Layer: spunbond polypropylene. Middle Layer: meltblown polypropylene filter media. Inner Layer: spunbond polypropylene. Earloops are soft non natural rubber latex,elastic loops. Nose Band: steel wires encased in polyethylene similar Fluid Resistance (ASTM F1862) Pass at 80 mmHg, Pass 120 mmHg Pass at 120 mmHg Same Bacterial Filtration Efficiency (ASTM F2101) ≥ 99.8 % 99.7 % Same. Meet Level 2 requirement Differential Pressure (Mil-M-36954C) 3.6~4.2 mmH2O/cm2 3.3~3.6 mmH 2O/cm2 Same. Meet Level 2 requirement Particle Filtration Efficiency (ASTM F2299) 99.74~99.95 % (at 0.1 microgram) 98 % Same. Meet Level 2 requirement Flammability (16 CFR 1610) Class I Class I Same Biocompatibility (ISO 10993-5, -10) Non-Cytotoxic, Non- Sensitizing, Non-Irritating Non-Cytotoxic, Non- Sensitizing, Non-Irritating Same

Discussion on

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 23, 2026