DECISION DATEMay 4, 2022PRODUCT CODEFYA

Indications for use

Plus Medical Chemotherapy Gowns are intended to protect healthcare personnel from exposure to chemotherapy drugs during preparation, handling and administration. The gowns are a closed back design, single use, disposable medical device provided sterile and non-sterile. Non-sterile gowns are to be sold in bulk to re-packager/re-labeler establishments for ethylene oxide (EtO) sterilization according to ISO 11135-1 prior to marketing to the end users and Sterile surgical gowns are to be sold directly to users after EtO sterilization validation to ISO 11135-1.

Plus Medical Chemotherapy Gown meets the barrier protection requirements of AAMI Level 4 per ANSI/AAMI PB70:2012. Liquid Barrier Performance and Classification of Protective Apparel and Drapes Intended for Use in Health Care Facilities.

Plus Medical Chemotherapy Gown has been evaluated for resistance to permeation of various chemotherapy drugs per ASTM F739-12 Standard Test Method for Permeation of Liquids and Gases through Protective Clothing Materials under Conditions of Continuous Contact. Testing data is provided per test procedure ASTM F739-12, the following 12 chemotherapy drugs has no breakthrough at the Standardized Breakthrough Rate of 0.1ug/cm2/minute, up to 480 minutes.

Test Chemotherapy Drugs Average Standardized Breakthrough Time

Carmustine (BCNU) [3.3mg/ml] >480mins

Cisplatin [1.0mg/ml] >480mins

Cyclophosphamide (Cytoxan) [20.0mg/ml] >480mins

Dacarbazine [10.0mg/ml] >480mins

Doxorubicin HCI [2.0mg/ml] >480mins

Etoposide [20.0mg/ml] >480mins

Fluorouracil [50mg/ml] >480mins

Methotrexate [25mg/ml] >480mins

Mitomycin C [0.5mg/ml] >480mins

Paclitaxel [6.0mg/ml] >480mins

Thio Tepa [10mg/ml] >480mins

Vincristine Sulfate [1.0mg/ml] >480mins

*No permeation was detected at either the minimum detectable permeation or 0.lug/cm2/minute.

When chemotherapy drugs are present, gown selection should be based on the specific type(s) of chemicals used. Users are recommended to review drug labeling or material safety data sheets for the chemicals being used to determine an adequate level of protection.

See the full product information製品情報をすべて見るには

Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。

Start free 7-day access7日間無料で利用するLog inログイン

OFFICIAL FDA SOURCES

FDA Record and Public Document Status

Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。

Information reviewed:情報の確認日: August 22, 2026