FDA DEVICE FACTS
Steinmann Pins and Kirschner Wires
Stryker GmbH
FDA-sourced product information for medical-device development research. Use the official FDA sources at the end of this page when the original public document wording is needed.医療機器開発の調査用に、FDA の公開情報から取った製品情報を示しています。公開文書の原文が必要なときは、このページの最後にある FDA の公式な出典をご覧ください。
Indications for use
The Steinmann Pins are intended to be used in conjunction with a compatible Stryker external supporting frame for immobilization of open and/or unstable fractures and where soft tissue injury may preclude the use of other fracture treatments such as IM rodding, casting and other means of internal fixation. The Kirschner Wires are intended for use in skeletal traction for alignment and reduction of long bone fractures, and as guide wires in hip pinning, and as fracture fixation devices in certain other small bone fractures.
• For use as guide wires in hip pinning procedures,
• For use in aligning and reducing long bone fractures,
• For use in securing temporary stabilization of bone fractures such as olecranon fractures; patella fractures; tib ia plateau fractures; small hand and foot bone fractures; humeral, radial and ulnar fractures.
• For use with cerclage wire/cable in treating greater trochanter fractures. Summary of Technologies: Steinmann Pins: The intended use of the subject devices (Steinmann Pins) are similar to those detailed in the predicate device (Apex Fixation Pins). There is no change in the fundamental scientific technology shared by both the subject device and predicate device. Kirschner Wires The intended use of the subject devices (Kirschner Wires) are similar to those detailed in the predicate device (Osteo Kirschner Wires). There is no change in the fundamental scientific technology shared by both the subject device and predicate device. Performance Data (Nonclinical): Non-Clinical Performance and Conclusions: The Steinmann Pins and Kirschner wires are single use instruments, sterilized by means of radiation; they are sterile stainless steel wires with diameter and lengths comparable to those of the predicate devices . The design is substantially equivalent to that of the predicate devices; the indications for use are included in those of the predicate devices; the material of the Steinmann Pins and Kirschner wire are the same as that of the predicate device. Moreover, Steinmann Pins and Kirschner wires conform to the international standard ISO 5838-1. Testing, therefore, is not needed to demonstrate that the subject devices are substantially equivalent to other legally marketed Steinmann Pins and Kirschner wires. Packaging tests were performed according ISO 11607-1 and ISO 11607-2. All bench tests performed in accordance with ASTM standards. Clinical Performance and Conclusions: Clinical data and conclusions were not needed for these devices to demonstrate substantial equivalence to the predicate devices.
Device description, AI/software, PCCP, evaluation and limitations are available with an account: seven days of full access after free registration, then with the paid plan.機器の説明、AI・ソフトウェア、PCCP、評価、制限事項は、アカウントでご覧いただけます。無料登録から 7 日間はすべて利用でき、その後は有料プランでご利用いただけます。
OFFICIAL FDA SOURCES
FDA Record and Public Document Status
Record and document link states are stored separately.FDA Record と公開文書のリンクの状態は、別々に記録しています。